Solution Type  Technical Instruction Sure

Solution  1021982.1 :   SL8500 - Troubleshooting PDU Power Supply Status Problems  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
276550


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Confidential for Partners and Oracle Support personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 9-May-2011.

Goal

Troubleshooting PDU Power Supply Status Problems.
( Power Distribution Unit )

Solution

Steps to Follow
Refer to actions below to troubleshoot PDU PS status issues:
PDU status signals to the HBX card:
-Cable with PN_4196045-01 routes up from the pdu_1 and the phase_a signal is on pin_11 and on pin_5 p306.
-Connects with cable PN_4196208-01 up to the HBX card via connector p208/209
 
Recommend:

-Check and reseat the cable w/ pn_4196208-01 at both ends; p306/307 at the bulkhead next to the pdu and connectors p208/209 at the HBX card.
-If no issues are found swap cable at both ends and recheck status information in an attempt to verify the cable.
-Check for bent pins on the HBX card connector; p208/209.
-Check mid plane connector for HBX card for bent pins.
-Swap HBX card with another library.
-The cable harness associated with the back of the PDU would be a significant effort to check and replace. I would only look at this cable if no other issues are found.
 
To gain access to pn_4196208-01:
-if standalone library; remove DEM side cover and access plate and drop the ECM.
-if PTP connected; remove arrays on rail_3 column 3 and 4, remove access panel.



SL8500, PDU PS Status problem, Power Distribution Unit, Power Supply, Troubleshooting, Sense failure debug Information, Status signals HBX