Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1305977.1
Update Date:2011-04-26
Keywords:

Solution Type  Technical Instruction Sure

Solution  1305977.1 :   How to Replace X4200 Fan Board:ATR:1453:0  


Related Items
  • Sun Fire X4200 Server
  •  
  • Sun Fire X4200 M2 Server
  •  
Related Categories
  • GCS>Sun Microsystems>CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Fire X4200 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Fire X4200 M2 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

Replace X4200 Fan Board

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Basic Sun hardware FE skills, familiarity or training for X4200 platform.

DELIVERY REQUIREMENT:
Schedule with maintenance window within contractual terms.

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:
Replace X4200 Fan Board

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server as described in Powering Off the Server.

2. If the server is in a rack, slide it far enough from the rack so that you can open the fan bay door. If you cannot safely view and access the component, remove the server from the rack.

3. Open the fan bay door and hold it open. See Opening the Fan Bay Door and Removing a Fan Module.

4. Remove the three fan modules that are connected to the fan connector board you are replacing. Grasp each fan module by its plastic strap and lift it straight up out of the fan bay.

5. Visibly inspect the remaining fans and all air openings for dirt, and clean if necessary.

6. Unfasten the single screw that secures the fan connector board to the chassis.

7. Slide the fan connector board toward the center of the chassis to disconnect it from the front I/O board and to release it from the two locating tabs on the chassis.

8. Lift the board straight up to remove it from the system.

9. Installation is the reverse of this procedure.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart system and have the System administrator verify functionality of system.

PARTS NOTE:
Nil

REFERENCE INFORMATION:
Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Service Manual and Diagnostics Guide
http://download.oracle.com/docs/cd/E19121-01/

TIME ESTIMATE:

15 minutes.
Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback