Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1306349.1
Update Date:2011-04-26
Keywords:

Solution Type  Technical Instruction Sure

Solution  1306349.1 :   How to Remove and Replace a X4200 DIMM:ATR:1460:0 [VIDEO]  


Related Items
  • Sun Fire X4200 Server
  •  
  • Sun Fire X4200 M2 Server
  •  
Related Categories
  • GCS>Sun Microsystems>CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Fire X4200 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun Fire X4200 M2 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

How to Remove and Replace a X4200 DIMM


Video - ATR 1460 (2:47)

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner

DELIVERY REQUIREMENT:

Schedule with customer within contractual terms.

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:

DIMM failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
System needs to be shutdown by the customer.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Power off the server.

2. Remove the Top Cover.
-Press down on the cover release button and, using the indent for leverage, slide the main cover toward the rear of the chassis approximately 0.5 inch.
-Grasp the cover by its rear edge and lift it straight up from the chassis
3. Locate the DIMM slot on the motherboard from which you will replace a DIMM, as DIMMs must be installed in pairs you'll also need to replace the companion DIMM to the one being replaced. DIMM 0 and 1 are a pair as are DIMM 2 and 3, position of the DIMMs differ in the x4200 from the x4200M2.

4. Rotate both DIMM slot ejectors outward as far as they will go. The DIMM is partially ejected from the socket.

5. Carefully lift the DIMMs straight up to remove it from the socket.

6. Install the DIMMs.
-Ensure that the DIMM slot ejectors at each end of the memory socket are fully open (rotated outward) to accept the new DIMM
-Align the notch in the bottom edge of the DIMM with the key in the DIMM socket
-Press down evenly on both top corners of the DIMM until the ejectors snap over the cutouts in the left and right edges of the DIMM
7. Install the top cover.

8. Connect all power cables.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

None

PARTS NOTE:

N/A

REFERENCE INFORMATION:

http://download.oracle.com/docs/cd/E19121-01/sf.x4200/index.html

TIME ESTIMATE:



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.