Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1309207.1 : How to Replace a Sun Blade X6250 Compact Flash Module:ATR:2616:0
In this Document
Applies to:Sun Blade X6250 Server Module - Version: Not ApplicableInformation in this document applies to any platform. GoalHow to Replace a Sun Blade X6250 Compact Flash Module.SolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) This component is a CRU and can be replaced by anyone. DELIVERY REQUIREMENT: This operation requires a complete power outage of the entire machine. Thus it needs to be planned according to the customer's wishes. Estimate AP Duration = 0.5 hours FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : Back up the information and shut down the system WHAT ACTION DOES THE ENGINEER NEED TO TAKE: 1.- If necessary, back up any data that is contained on the compact flash module. 2.- Power off the server and remove the server module from the chassis. 3.- Remove the main cover. 4.- Locate the compact flash module under the REM at the back of the server module. 5.- Grasp the card, push down slightly, and pull card out. 6.- Installation is the reverse of this procedure. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Restart the system PARTS NOTE: No parts needed REFERENCE INFORMATION: http://download.oracle.com/docs/cd/E19045-01/ Attachments This solution has no attachment |
||||||||||||
|