Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1310001.1 : How to Replace a T5120/T5220 XAUI Card:ATR:1384:0
In this Document
Applies to:Sun SPARC Enterprise T5120 Server - Version: Not ApplicableSun SPARC Enterprise T5220 Server - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. GoalHow to remove and replace a T5120/T5220 XAUI CardSolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner. DELIVERY REQUIREMENT: Schedule with customer within contractual terms. TIME ESTIMATE: 1 Hour FIELD ENGINEER INSTRUCTIONS PROBLEM OVERVIEW: Faulty XAUI Card WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. Customer should shut the operating system down gracefully (using "init 0"), and after the system has shut down Switch from the system console to the -> prompt by typing the #. (Hash Period) key sequence. At the -> prompt, type the stop /SYS command. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: *** Follow standard ESD procedures to avoid Electrostatic Discharge 1. Disconnect all power cables 2. Remove the Top Cover -Unlatch the fan module door by pulling the release tabs back to release the door -Press the top cover release button and slide the top cover to the rear about a 0.5 inch -Lift up and remove the cover Removal: 1. Locate the XAUI card that you want to remove. Note its corresponding riser board. 2. Unplug all data cables from the card. Note the location of all cables for reinstallation later. 3. Remove the riser board. 4. Carefully remove the XAUI card from the riser board connector. 5. Place the XAUI card on an antistatic mat. Installation: 1. Unpack the replacement XAUI card and place it on an antistatic mat. 2. Locate the proper XAUI slot for the card you are replacing. 3. Remove the XAUI riser board. 4. Insert the XAUI card into the correct slot on the riser board. 5. Replace the XAUI riser. 6. Install the top cover. 7. Slide the server into the rack. 8. Connect any data cables required to the XAUI card. Route data cables through the cable management arm. 9. Connect the power supplies. Note - As soon as the power cords are connected, standby power is applied. Depending on how the firmware is configured, the system might boot at this time. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Power on the server and restart software applications per applicable administration guides to resume system operation. PARTS NOTE: None REFERENCE INFORMATION: Sun SPARC Enterprise® T5120 and T5220 Servers Service Manuals http://download.oracle.com/docs/cd/E19839-01/ http://download.oracle.com/docs/cd/E19637-01/ Attachments This solution has no attachment |
||||||||||||
|