Goal

How to remove and replace a T5120 Fan module

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner is required.

DELIVERY REQUIREMENT:

Schedule for immediate replacement can be planned within contractual terms.

TIME ESTIMATE: 1H

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:

Fan Module Failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software system shutdown. Then power down the system and disconnect the Power Cord.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1) Remove a Fan Module

1. Extend the server to the maintenance position.

2. Lift the latch and open the top cover door.

3. The faulty fan module is identified with a corresponding fault LED.

4. Grasp the fan module by green fan module label and lift the module up out of the chassis.

2) Install a Fan Module

1. With the top cover door open, install the replacement fan module into the server.

2. Apply firm pressure to fully seat the fan module.

3. Verify that the Fan Fault LED on the replaced fan module is off.

4. Close the top cover door.

5. Verify that the system Fan Fault LED, Service Required LEDs, and the individual fan module Fault LED are off.

6. Run the ILOM show faulty command to verify that the fan fault has been cleared.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:

Part location

REFERENCE INFORMATION:

Sun SPARC Enterprise T5120 Server Service Manual -