Solution Type Technical Instruction Sure Solution 1317596.1 : How to Replace an X4440 Air Duct:ATR:2181:0
In this Document
Applies to:Sun Fire X4440 Server - Version: Not ApplicableInformation in this document applies to any platform. GoalHow to replace an X4440 Air Duct:ATR:2181:0SolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED: This customer-replaceable unit can be replaced by anyone DELIVERY REQUIREMENT: Schedule with maintenance window Estimate AP Duration = 2.5 hours FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : 1. Power off server 2. Disconnect power cords from power supply WHAT ACTION DOES THE ENGINEER NEED TO TAKE: 1. Slide server out of rack 2. Attach antistatic wrist strap 3. Remove top cover Removing the Air Duct 1. Remove mezzanine tray, to access air duct 2. Lift air baffle out of mezzanine tray 3. Slide motherboard air duct to right to disengage pin on left side 4. Slide air duct to left to disengage pin on right side 5. Move air duct towards back to clear lip on midwall 6. Lift air duct out of server 7. Set air duct aside Installing the Air Duct 1. Reverse the Removing process Return Server to Operation 1. Reinstall mezzanine tray 2. Install top cover 3. Install server into rack OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Bring system back online PARTS NOTE: REFERENCE INFORMATION: http://download.oracle.com/docs/cd/E19121-01/sf.x4440/820-3836-14/820-3836-14.pdf Attachments This solution has no attachment |
||||||||||||
|