Solution Type Technical Instruction Sure Solution 1320253.1 : How to Replace a X6270 M2 PCIe Fabric Expansion Module:ATR:2281:0
In this Document
Applies to:Sun Blade X6270 M2 Server Module - Version: Not ApplicableInformation in this document applies to any platform. GoalHow to replace a X6270 M2 PCIe Fabric Expansion Module (FEM)SolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) CRU DELIVERY REQUIREMENT: schedule with maintenance window Estimate AP Duration = 0.5 hours FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : This procedure requires a complete shut down of the equipment. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: 1.- Removing FEM Card. a. Power off the server and disconnect the power cord (s) from the power supply (s). b. Remove the server from the rack. c. Attach an antistatic wrist strap. d. Remove the top cover. e.-Remove the existing FEM card. 2.- Installing FEM Card. Perform the following steps to install the FEM card: - Slide the FEM card at an angle into the support bracket. - Press the FEM card carefully into the connector. - Connect the FEM to the motherboard. - Install the cover on the server. 3.-Return the server to operation. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Boot up system and verify full functionality PARTS NOTE: REFERENCE INFORMATION: Sun Blade X6270 M2 Server Module Service Manual http://download.oracle.com/docs/cd/E19474-01/ Attachments This solution has no attachment |
||||||||||||
|