Solution Type Troubleshooting Sure Solution 1008191.1 : Sun StorageTek 33x0 SCSI Array: Troubleshooting SCSI Devices from the Operating System
PreviouslyPublishedAs 211250 Description Troubleshooting SCSI Devices from the Operating System Steps to Follow Please validate that each troubleshooting step below is true for your environment. The steps will provide instructions or a link to a document, for validating the step and taking corrective action as necessary. The steps are ordered in the most appropriate sequence to isolate the issue and identify the proper resolution. Please do not skip a step. Step 1 - Identify which device path is not seen by looking at format or /var/adm/messages.This will be needed in step 2. Example: /devices/pci@1f,4000/pci@5/scsi@4 Step 2 - Verify the HBA can be seen from the OS Refer to < Document: 1005314.1 > Sun StorageTek 33x0 SCSI Array: How to verify SCSI HBA Connectivity Step 3 - Sun Solaris only supports Veritas DMP for SCSI multipathing, please verify Multipathing is enabled correctly. Refer to < Document: 1011302.1> "Verifying DMP Health" for VxDMP Step 4 - Verify StorEdge array hardware and configuration is optimal. Refer to < Document: 1005313.1 > Troubleshooting Sun StorEdge 33x0/351x Configuration Step 5 - Verify lun setting within the sd.conf file. Refer to Editing the sd.conf file , Appendix D2, in the Sun StorEdge 3000 Family Installation, Operation, and Service Manual available from http://www.oracle.com/technetwork/indexes/documentation/index.html/ At this point, if you have validated that each troubleshooting step above is true for your environment, and the issue still exists, further in-depth troubleshooting is required. Please provide supporting data and open a Service Request.
Product Sun StorageTek 3310 SCSI Array Sun StorageTek 3320 SCSI Array Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: Domain Lead: sue.copeland@sun.com Feedback Alias: storage-os-disk-low-domain@sun.com
3110, 3120, 3310, 3320, SCSI, normalized Previously Published As 89050 Change History Date: 2007-08-23 User Name: 7058 Action: Approved Comment: Links fixed. Version: 8 Date: 2007-08-23 User Name: 7058 Action: Update Started Comment: External sunsolve links pointing to internal sunsolve server. Version: 0 Date: 2007-07-03 User Name: 7058 Action: Approved Comment: This doc is finally ready to publish. Notes for Normalizaton: Subset of: N/A Subset Root path: N/A References: 86532, 89038, 89031 Project: Minnow Normalization Version: 7 Attachments This solution has no attachment |
||||||||||||
|