Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-75-1012661.1
Update Date:2009-05-12
Keywords:

Solution Type  Troubleshooting Sure

Solution  1012661.1 :   Troubleshooting Multiple Disk Failures in a Sun StorEdge[TM] T3 Array  


Related Items
  • Sun Storage T3 Array
  •  
  • Sun Storage T3+ Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
217414


Description
This document describes how to identify and resolve multiple drive failures within a single volume on the array.

In order to provide you the most accurate fix, please validate that each statement under the symptoms below is true for your environment.

These symptoms will hyperlink you into a relevant content that will 1) tell you how to validate the listed symptom and 2) how to fix the symptom if it is true for your environment. The listed symptoms are ordered in the most appropriate sequence to isolate the issue and be certain about the related fix. Please do not skip a step.

Symptoms:

- 'fru stat' shows 2 or more disk failures

- Volume fails to recon after disk replacement

Environmental Considerations:

- Multiple disk failures are only for disks in the same volume.



Steps to Follow
Troubleshooting Steps:

NOTE:  This is a sub-set of Troubleshooting <Document: 1009745.1> : "Troubleshooting Sun StorEdge[TM] T3 Disk Failures."  

1.  Set expectations.  At this point the possibility of data loss is high.  There is one possible procedure that can be used by Sun to save data. Contact Sun.



Product
Sun StorageTek T3+ Array
Sun StorageTek T3 Array

Internal Comments
Place Sun Internal-Use Only content here. This content will be published to internal SunSolve[SM] only.

The steps below will help resolve a dual disk failure in the
same volume for a T3 array.



1.  Set expectations. At this point the possibility
of data loss is high.  There is one possible procedure to save
data, s
ee Technical Instruction <Document: 1012157.1> : Sun StorEdge[TM] T3+ Array:
Re-Creating Vol-Slice LUNs ),however you should prepare to
restore from backup.


2.  Replace disks.


3.  Rebuild orginal volume.


4.  Restore data from backup.

The Knowledge Work Queue for this article is KNO-STO-MIDRANGE_DISK.

The domain lead is:  curtis.decotis@sun.com

storage-os-disk-mid-domain@sun.com


T3, T3+, disk, drive, fault, failed, multiple, audited, normalized
Previously Published As
86540

Change History
Date: 2007-11-13
User Name: 7058
Action: Approved
Comment: Changed sunsolve2.central reference to sunsolve.central in internal only section.
Version: 7
Date: 2007-11-13
User Name: 7058
Action: Update Started
Comment: fix links.
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.