Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Troubleshooting Sure Solution 1019933.1 : SL8500 - Drive and Rail Power Supply Troubleshooting Information
PreviouslyPublishedAs 249286 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential for Partners and Oracle Support personnel
Applies to:Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later [Release: N/A and later]All Platforms Checked for relevance on 9-May-2011. PurposeDrive and Rail Power Supply Troubleshooting Information.Fixing "Yellow" Power Supply alerts in the SL Console. Last Review DateMay 9, 2011Instructions for the ReaderA Troubleshooting Guide is provided to assist
in debugging a specific issue. When possible, diagnostic tools are included in the document
to assist in troubleshooting.
Troubleshooting DetailsSteps to FollowRefer to the attach document to trouble shoot drive and rail power issues on the library. All drive power supplies are reported through the HBT card through 4 cables that only differ in length. SL8500, Power Supply Alert, Yellow warning on SL Console, Signal pin out, Cable connector, Rail power supply, Cable and pin out list, HBY DRIVE Power Supply Sense Connections, HBF DRIVE Power Supply Sense Connections, HBX RAIL Power Supply Sense Connections, HBF RAIL Power Supply Sense Connections Attachments This solution has no attachment |
||||||||||||
|