This section provides tips (when available) for the
most common repair procedures for the Sun SPARC Enterprise T5120 Server. The repair
procedures are provided in the following manual:
Component |
Tips |
Fan |
-
Fan Connectors on the Fan Boards are being damaged upon Fan removal/replacement for systems using the Jake 1U chassis.
(FAB 1019695.1).
|
Miscellaneous |
-
Console behavior is inconsistent when a graphics device and keyboard are specified for console use.
This occurs when the OpenBoot variables 'input-device' and 'output-device' are set to anything other
than the default value of 'virtual-console'.
(FAB 1018990.1).
|
Removable Media |
-
First Issue: DVD Drive Read and Write Errors and/or media damage
possibly resulting in the DVD Drive being unusable at any level of system operation.
Second Issue: DVD Backplane connector damage may result from a missalignment between
the DVD Drive and backplane connector.
(FAB 1019082.1).
-
DVD does not align during installation of the DVD and can cause damage to the DVD and/or backlplane.
(FAB 1019599.1).
-
Sun SPARC Enterprise T5x20 and T5x40 PATA DVD won't Boot or Mount.
(FAB 1020828.1).
|
System Board |
-
Replacing Motherboard in T5220 Plus or T5120 Plus requires workaround and/or firmware upgrade.
(FAB 1019881.1).
|
System Firmware |
-
IBM DB2 database fails on T5120/T5220 with system firmware version 7.0.3.b due to dmmu fault addresses
not sign-extended.
(FAB 1019111.1).
|
Power Distribution Board |
- If replacing a defective PDB, you must move the
bus bar to the new board and program the chassis serial number using the
setscn command. Reference the Service Manual.
|