Backplane/Centerplane
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
380-1504 |
C4 Backplane, |
n/a |
|
|
n/a |
n/a |
380-1533 |
C4 Backplane |
n/a |
|
|
n/a |
NOTE: A special tool is needed to replace the backplane (part number 380-1504). The tool is a #10 Torx driver, at least 18 inches long. If the tool is not available then replace the complete chassis (part number 380-1503).
|
Cables
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X9733A-Z Price
|
537-1082 [F]
|
Fibre Channel Optical Cable LC/LC, 5M, |
n/a |
X1138A 1
[S]
|
530-2538
[F]
|
Ultra-3 SCSI cable, VHDCI/VHDCI, 2M |
n/a |
X3830A 2
[S]
|
530-2454
[F]
|
External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 4M |
n/a |
X3831A 3
[S]
|
530-2455
[F]
|
External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 10M |
n/a |
X3832A 4
[S]
|
530-2453
[F]
|
External SCSI Cable, HD68 to VHDCI, 2M |
n/a |
n/a |
380-1558 |
Hand Umbilical Cable |
n/a |
|
|
n/a |
1 Used for C4 SCSI Controller to host HBA connection.
2 For use with SG-XPCI2SCSI-LM320, SG-XPCI1SCSI-LM320 HBAs or system on-board SCSI ports.
3 For use with SG-XPCI2SCSI-LM320, SG-XPCI1SCSI-LM320 HBAs or system on-board SCSI ports.
4 For connection of second drive directly to the host HBA.
|
Fibre Channel
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SG-XFCCARD2-C |
380-1300 |
LVD SCSI to Fibre Channel Card |
n/a |
|
- LVD SCSI to Fibre Channel Card
|
n/a |
SG-XFCCARD2-C-Z
[S]
|
380-1390 |
LVD SCSI to Fibre Channel Card |
n/a |
|
- LVD SCSI to Fibre Channel Card,
|
n/a |
Miscellaneous
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SG-XMAGLTO-C |
380-1302 |
LTO Magazine |
n/a |
|
|
n/a |
SG-XMAGSDLT-C |
380-1303 |
SDLT Magazine |
n/a |
|
|
n/a |
n/a |
380-1503 [F]
|
C4 0 Drive Chassis, L |
n/a |
|
|
n/a |
n/a |
380-1506 |
C4 Hand Assembly, |
n/a |
|
|
n/a |
n/a |
380-1532 |
C4 0 Drive Chassis |
n/a |
|
|
n/a |
n/a |
380-1534 |
C4 Hand Assembly |
n/a |
|
|
n/a |
Power
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SG-XREDPWR-C |
380-1301 |
Redundant Power Supply |
n/a |
|
|
n/a |
SG-XREDPWR-C-Z
[S]
|
380-1391 |
Redundant Power Supply |
n/a |
|
- Redundant Power Supply, L
|
n/a |
Rack
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SR9-XKM038A-IP 5
|
595-7128
|
Sun Rack 900-38 with PDS |
n/a |
SRK-XAZ042A-IP 6
|
594-0632
|
Sun Rack 1000-42 with PDS |
n/a |
SRK-XRS038A-IP 7
|
595-7369
|
Sun Rack 1000-38 with PDS |
n/a |
X6826A |
595-6714 8
|
Filler Panel Kit for Sun Rack |
n/a |
X6828A
[S]
|
595-6715 |
Power Cable for Sun Rack, |
n/a |
5 Up to nine (9) C4 Libraries can be installed in the Sun Rack 900-38.
6 Up to ten (10) C4 Libraries can be installed in the Sun Rack 1000-42.
7 Up to nine (9) C4 Libraries can be installed in the Sun Rack 1000-38.
8 Install rack filler panels in any unused rack space for optimum air flow.
|
Removable Media
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SG-MEDLTO2-20B |
390-0226 |
LTO2 200GB Data Cartridge (Package of 20, Barcoded) |
n/a |
SG-MEDLTO3-20B |
390-0227 |
LTO3 400GB Barcoded Data Cartridge (Package of 20) |
n/a |
SG-MEDLTOCL-10B |
390-0228 |
LTO Cleaning Cartridges (Package of 10, Barcoded) |
n/a |
SG-XLIBLTOS-C4 |
594-1710 |
38-Slot LTO Library Base |
n/a |
|
- 38-Slot LTO SCSI Library Base
|
n/a |
SG-XLIBSDLTS-C4 |
594-1711 |
32-Slot SDLT Library Base |
n/a |
|
- 32-Slot SDLT SCSI Library Base
|
n/a |
SG-XMEDLTO3-10 9
|
390-0224 |
LTO3 400GB Non-barcoded Data Cartridge (Package of 10) |
n/a |
SG-XTAPLTO2S-C |
380-1295 |
LTO2 SCSI Tape Drive |
n/a |
|
|
n/a |
SG-XTAPSDLT6S-C |
380-1298 [F]
|
SDLT600 SCSI Tape Drive |
n/a |
|
|
n/a |
DLTS4-FC4G-C4-Z
[S]
|
380-1541 |
C-Series DLT-S4 4Gb FC Tape Drive |
n/a |
|
- C-Series DLT-S4 4Gb FC Tape Drive,
|
n/a |
DLTS4-SCSI-C4-Z
[S]
|
380-1540 |
C-Series DLT-S4 SCSI Tape Drive |
n/a |
|
- C-Series DLT-S4 SCSI Tape Drive ,
|
n/a |
LTO3-HP4FC-C4-Z
[S]
|
380-1552 |
LTO3-HP-FC 4Gb Tape Drive |
n/a |
|
- LTO3-HP-FC 4Gb Tape Drive,
|
n/a |
SG-XMEDLTO200GB-10
[S]
|
390-0147 [S]
|
LTO2 200GB Data Cartridge (Package of 10, Non-barcoded) |
n/a |
SG-XMEDLTOUNVCL-10
[S]
|
390-0134 [S]
|
LTO Cleaning Cartridge (Package of 10, Non-barcoded) |
n/a |
SG-XMEDSDLT2D-20
[S]
|
390-0163 [S]
|
SDLT 600 300GB Data Cartridges (Package of 20, Non-barcoded) |
n/a |
SG-XMEDSDLTCL-10
[S]
|
390-0140 [S]
|
SDLT Cleaning Cartridge, SDLT Cleaning Cartridge (Package of 10, Non-barcoded) |
n/a |
SG-XTAPLTO2S-C-Z
[S]
|
380-1387 10
|
LTO2 LVD SCSI Tape Drive (full-height) |
n/a |
|
- LTO2 LVD SCSI Tape Drive (full-height),
|
n/a |
SG-XTAPLTO3FC-C
[S]
|
380-1489 11
|
LTO3 FC Tape Drive |
n/a |
|
|
n/a |
SG-XTAPLTO3S-C
[S]
|
380-1296 |
LTO3 SCSI Tape Drive |
n/a |
|
|
n/a |
SG-XTAPLTO3S-C-Z
[S]
|
380-1388 12
|
LTO3 LVD SCSI Tape Drive (full-height) |
n/a |
|
- LTO3 LVD SCSI Tape Drive (full-height),
|
n/a |
SG-XTAPSDLT6FC-C
[S]
|
380-1490 13
[F]
|
SDLT600 FC Tape Drive |
n/a |
|
|
n/a |
SG-XTAPSDLT6S-C-Z
[S]
|
380-1389 14
[F]
|
SDLT600 LVD SCSI Tape Drive |
n/a |
|
- SDLT600 LVD SCSI Tape Drive,
|
n/a |
9 Backward read/write compatible with LTO2; backward read compatible
with LTO1.
10 This unit has an 30 MB/sec native throughput and uses 200GB cartridges.
11 This unit has an 80 MB/sec native throughput and uses 400GB cartridges.
12 This unit has an 80 MB/sec native throughput and uses 400GB cartridges.
13 This unit has an 36 MB/sec native throughput and uses 300GB cartridges.
14 This unit has an 36 MB/sec native throughput and uses 300GB cartridges.
|
SCSI
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SGXPCI1SCSILM320-Z Price
|
375-3366
|
PCI/PCI-X Single Ultra320 SCSI Adapter |
n/a |
SGXPCI2SCSILM320-Z Price
|
375-3365
15
|
PCI Dual Ultra320 SCSI Adapter, L |
n/a |
SG-XPCI1SCSI-LM320
[S]
|
375-3255
|
PCI/PCI-X Single Ultra320 SCSI Adapter |
n/a |
SG-XPCI2SCSI-LM320
[S]
|
375-3191
|
PCI/PCI-X Dual Ultra320 SCSI Adapter |
n/a |
X2222A
[S]
|
501-5727
|
Dual FastEthernet / Dual SCSI PCI Adapter |
n/a |
X4422A
[S]
|
501-6635
|
Dual GigabitEthernet / Dual SCSI PCI Adapter |
n/a |
X6758A
[S]
|
375-3057 16
|
PCI Dual Ultra3 SCSI Host Adapter (LVD) |
n/a |
15 Ultra320 SCSI HBA (375-3365-01 REV 52) FCode 1.13 fails to work on all Sun Platforms, replace it with 375-3365-02 REV 50.
See Problem article 1013105.1.
16 The necessary drivers (SUNWqus, SUNWqusu, SUNWqusx, & SUNWqusux) and patches for this product are not included in Solaris 8 or 9, but must be downloaded. Please see How To article
1018123.1 for details.
NOTE: For FRU/CRU status, see host system's Full Components List.
|
System Controller
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
380-1507 |
C4 System Control Board (SCSI), |
n/a |
|
- C4 System Control Board (SCSI),
|
n/a |
n/a |
380-1508 |
C4 System Control Board (FC) |
n/a |
|
- C4 System Control Board (FC)
|
n/a |
n/a |
380-1535 |
C4 System Control Board (SCSI) |
n/a |
|
- C4 System Control Board (SCSI)
|
n/a |
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
|
No Artwork Currently Available
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown
|
Code |
Manufacturing Part# |
Description |
NS |
n/a |
Ultra-320 SCSI Cable, VHDCI68 to HD68, .5m (SCSI Controller to First Drive) |
NS |
n/a |
Ultra-320 SCSI Cable, HD68 to HD68, .4m (First Drive to Second Drive) |
NS |
n/a |
Rackmount Kit |
NS |
n/a |
Ultra-320 SCSI Cable, VHDCI68 to HD68, .75m |
NS |
n/a |
Terminator |
NS |
n/a |
Ethernet Crossover Cable |
NS |
n/a |
Power Cord, Quantum 17-00606 |
|