Sun Fire[tm] X4450, RoHS:YL Server: Repair Procedures
This section provides tips (when available) for the
most common repair procedures for the Sun Fire X4450. The repair
procedures are provided in the following manual:
The following table provides tips associated with each component.
Component |
Tips |
Miscellaneous |
-
On Red Hat Enterprise Linux 4 (RHEL4) GA through RHEL4.5, it is possible for the memory management
data of a process to be modified while the process is still active on another processor, causing the system to hang.
Reference FAB 1019068.1.
|
PCI |
-
PCI Retainer Bar improvement on specific systems. Reference FAB 1020282.1.
|
Power Supplies |
-
FCO A0306-1: Some Sun Fire, SPARC Enterprise, and Sun Storage Systems using Power Supply Units within a certain date code range may experience a Thermal Event upon PSU failure.
Reference FAB 1020545.1.
|
Remote Mangement |
-
First Issue:64 Intel-based platforms transitioning from ELOM to ILOM.
(FAB 1019481.1).
|
Removable Media |
-
First Issue: DVD Drive Read and Write Errors and/or media damage possibly resulting in the DVD Drive being unusable at any level of system operation. Second Issue: DVD Backplane connector damage may result from a missalignment between the DVD Drive and backplane connector.
(FAB 1019082.1).
-
DVD does not align during installation of the DVD and can cause damage to the DVD and/or backlplane.
(FAB 1019599.1).
|
|