Sun StorEdge[tm] 5210 NAS: Repair Procedures
This section provides tips (when available) for the most common repair procedures for the StorEdge 5210 NAS. The repair procedures are provided in the following manual:
Sun
StorEdge 5210 NAS Hardware Installation, Configuration, and User Guide (817-6660)
Component
|
Tips
|
Disk Drive
|
-
Seagate Cheetah 7 FC-AL and SCSI disk drives with serial numbers
below 60000 are experiencing a higher than expected failure rate due to a spindle
motor issue (FCO A0239-1).
|
SE5210 LSI MegaRAID Board
|
-
If the SE5210 LSI MegaRaid board battery is fully discharged,
in the event of a power outage any data in the cache will be lost (FCO A0257-1).
|
RAID Management
|
-
Improper usage of RAID Management tools such as Santricity (NRM) and
CAM (Common Array Management) to administer the Sun StorEdge 5210/5310 and
Sun StorageTek 5320/5220 can lead to unplanned outages including data
corruption and data loss.
(FAB 1000787.1).
|
|
|