This section provides the most common repair procedures for the 
  Sun Blade 100 workstation. The written procedures below are links to the  Sun 
  Blade 100 Service Manual (806-3416).
Sun 
  Blade 100 Service Manual (806-3416). 
   
    | Component | Tips | 
   
    | CPU Module | 
        CPU die temperature reported by 'prtdiag' and 'prtpicl' is incorrect 
          on Sun Blade 100/150 and is not a supported function (FIN I1021-1). | 
   
    | Disk Drive (Primary) | 
        Installation of a Seagate ST320011A HDD into the drive tray of a Sun 
          Blade 100 will unseat the hard drive tray latch cover (FIN I0787-1).New 20.1GB disk drive is being released in a limited number of Sun 
          Blade 100 systems (FIN I0872-1). | 
   
    | Disk Drive (Secondary) | 
        Installation of a Seagate ST320011A HDD into the drive tray of a Sun 
          Blade 100 will unseat the hard drive tray latch cover (FIN I0787-1).New 20.1GB disk drive is being released in a limited number of Sun 
          Blade 100 systems (FIN I0872-1). | 
   
    | Memory | 
        When an ECC error occurs on Sun Blade 100, Solaris incorrectly identifies 
          the faulty DIMM (FIN I0798-1).Idle Sun Blade 100 systems may experience unscheduled reboots (FCO 
          A0205-1). | 
   
    | PCI Card | 
         
           
            The SunPCi II board may not seat properly in the 
              Sun Blade 100 chassis (FIN I0739-1 ).
          
            SunPCi II and SunPCi IIpro cards may not respond 
              after rapid/successive power cycling (FCO A0186-1 ). | 
   
    | Smart Card Reader | 
        Solaris 8 patches required for Smart Card Reader operation on Sun 
          Blade 100, 1000, and 2000 systems (FIN I0868-1). | 
   
    | System Board | 
        New system boards with part number 375-3106 require special patches. 
          Refer to the Sun Blade 100 Motherboard Update and Sun PGX64 Patch 
          Procedures,  816-7660.New Motherboard FRU for Sun Blade 100 systems requires modified installation 
          procedure (FIN I0843-1).'prtconf' command may return wrong System Board part number on Sun 
          Blade 100 systems (FIN I0923-1).SunBlade 100 systems may not auto-restart after a power failure (FCO 
          A0204-1). |