This section provides the most common repair procedures for the
Sun Blade 100 workstation. The written procedures below are links to the Sun
Blade 100 Service Manual (806-3416).
Component |
Tips |
CPU Module |
- CPU die temperature reported by 'prtdiag' and 'prtpicl' is incorrect
on Sun Blade 100/150 and is not a supported function (FIN I1021-1).
|
Disk Drive (Primary)
|
- Installation of a Seagate ST320011A HDD into the drive tray of a Sun
Blade 100 will unseat the hard drive tray latch cover (FIN I0787-1).
- New 20.1GB disk drive is being released in a limited number of Sun
Blade 100 systems (FIN I0872-1).
|
Disk Drive (Secondary) |
- Installation of a Seagate ST320011A HDD into the drive tray of a Sun
Blade 100 will unseat the hard drive tray latch cover (FIN I0787-1).
- New 20.1GB disk drive is being released in a limited number of Sun
Blade 100 systems (FIN I0872-1).
|
Memory |
- When an ECC error occurs on Sun Blade 100, Solaris incorrectly identifies
the faulty DIMM (FIN I0798-1).
- Idle Sun Blade 100 systems may experience unscheduled reboots (FCO
A0205-1).
|
PCI Card |
-
The SunPCi II board may not seat properly in the
Sun Blade 100 chassis (FIN I0739-1).
-
SunPCi II and SunPCi IIpro cards may not respond
after rapid/successive power cycling (FCO A0186-1).
|
Smart Card Reader |
- Solaris 8 patches required for Smart Card Reader operation on Sun
Blade 100, 1000, and 2000 systems (FIN I0868-1).
|
System Board |
- New system boards with part number 375-3106 require special patches.
Refer to the Sun Blade 100 Motherboard Update and Sun PGX64 Patch
Procedures, 816-7660.
- New Motherboard FRU for Sun Blade 100 systems requires modified installation
procedure (FIN I0843-1).
- 'prtconf' command may return wrong System Board part number on Sun
Blade 100 systems (FIN I0923-1).
- SunBlade 100 systems may not auto-restart after a power failure (FCO
A0204-1).
|