This section provides the most common repair procedures for the 
  Sun Fire 280R. The following links are located in the  Sun 
  Fire 280R Server Service Manual (806-4807).
Sun 
  Fire 280R Server Service Manual (806-4807).
   
    | Component | Tips | 
   
    | CPU Module | 
        Service procedures for replacement of early-release UltraSPARC[tm] 
          III modules with pre-fetch pipeline problems (FIN I0658-1). 
        Guidelines for understanding and diagnosing UltraSPARC III Level 2 
          (L2) SRAM Cache Memory Errors (FIN I0887-1). 
         | 
   
    | Disk Drive | 
        
           Improved firmware for Seagate 10K.6 disk drives will reduce the incidence of unexpected outages due to a spindle motor issue (FIN I1136-1 ).Fujitsu 73GB HDD will not be recognized during a 'boot net' operation 
          on Sun Blade 2000 or Sun Fire 280R platforms (FIN I0963-1).Power management issue causes loss of access to internal fiber channel 
          disks on the Sun Blade 1000/2000, Sun Fire V880, V480, and 280R (FIN 
          I0888-1). 
        Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible 
          to label corruption (FIN I0816-1).Seagate Cheetah 7 146GB FC-AL and 73 GB FC-AL disk drives
          may experience higher than expected failure rates due to
          spindle motor failure (FCO A0256-1). 
        Error installing Solaris on ST318304 FC-AL disk drives: Could not 
          create Solaris disk label (VTOC) (Problem article 1005941.1).Recovering from a failed FCAL boot disk (Problem article 1008580.1).Veritas Volume Manager 3.X - Procedure to Replace Internal Disks controlled by VxVM or not in Sun Fire[TM] 280R, V480 and V880 Systems 
          (How To article 1003122.1).Correcting device paths when replacing fiber boot disks after a ufsrestore 
          (Infodoc 1003103.1). 
         | 
   
    | Disk Drive (Hot-Plug Operation) | 
        Power management issue causes loss of access to internal fiber channel 
          disks on the Sun Blade 1000/2000, Sun Fire V880, V480, and 280R (FIN 
          I0888-1). 
        Veritas Volume Manager 3.X - Procedure to Replace Internal Disks controlled by VxVM or not in Sun Fire[TM] 280R, V480 and V880 Systems (How To article 1003122.1).Correcting device paths when replacing fiber boot disks after a ufsrestore 
          (Infodoc 1003103.1). | 
   
    | Memory | 
        Best Practices Guide for Memory Errors for diagnosing UltraSPARC III 
          memory errors now available (FIN I1018-1).New 256MB and 512MB LC1 DIMMs are now available ONLY for the Sun Blade 
          1000/2000 and Sun Fire 280R platforms (FIN I0883-1).Diagnosing Main Memory errors versus L2SRAM errors on UltraSPARC III 
          and UltraSPARC III Cu systems (FIN I0954-1).On certain Sun Systems a small number of 512MB and 1GB Micron DIMMs may experience premature failures with Uncorrectable Memory Error (UE) messages.  (FAB 1000920.1) (formerly FCO A0285-1)A sub-population of DIMMs that shipped between 2001 and 2002
	  on the below platforms are showing significantly lower
	  reliability than expected (FCO A0253-1).Systems containing 256MB Samsung B-die DIMMs, having a module date 
          code between 0115 and 0127 (built between weeks 15 and 27 of 2001), 
          may experience Uncorrectable Memory Errors (UE). This can lead to System 
          Panics (FCO A0223-1). | 
   
    | PCI Card | 
         
           
            UltraSPARC III systems may panic due to a conflict 
              between the Schizo 2.4 ASIC and the GigaSwift Ethernet PCI Card 
              (FIN I0874-1 ).
          
            SunPCi II and SunPCi IIpro cards may not respond 
              after rapid/successive power cycling (FCO A0186-1 ). | 
   
    | Power Distribution Board | 
        Power supplies in position PS0 and PS1 of a very small number of Sun Fire 
          280R systems may have cracked connectors, resulting in loss of power 
          from that power supply (FIN I0992-1). | 
   
    | Power Supply | 
        Power supplies in position PS0 and PS1 of a very small number of Sun Fire 
          280R systems may have cracked connectors, resulting in loss of power 
          from that power supply (FIN I0992-1). | 
   
    | System Board | 
        UltraSPARC III and III+ based platforms could be susceptible to UCC 
          errors that may cause system panics (FIN I0856-1). 
         |