FAB
|
Implementation
|
Synopsis
|
Last Modified Date
|
A0208-3 |
U
|
440MHz and 450MHz UltraSPARC II Modules in Ultra 60/80, Enterprise 220R/420R and Netra t platforms may experience Red State Exception, Send Mondo Timeout and hard hangs |
Mar 29 2004
|
A0186-1 |
U
|
SunPCi II and SunPCi IIpro cards may not respond after rapid/successive power cycling. |
Dec 03 2001
|
A0168-1 |
U
|
Any PCI card may not seat properly in E220R and E420R systems. |
Sep 06 2000
|
A0167-1 |
C
|
VRM Interposer board (375-0094-01) can cause intermittent system resets in the Enterprise 220R. |
Sep 12 2000
|
A0166-1 |
U
|
When installing the DDS-3 tape drive option (X6286A) in either a E420R or E220R will find that the peripheral D.C. power cable is short by 3-inches. |
Apr 20 2000
|
A0164-1 |
C
|
Systems with FC100/P cards (QL2100 PCI FC-AL HBA) having Molex optical transceivers, may cause increasing numbers of loop errors, excessive LIPs, and SCSI parity errors as they age. |
May 12 2000
|
I0743-1 |
R
|
Rack-mounted Enterprise 220R, 420R and Sun Fire 280R systems may bind with adjacent systems if improperly installed |
2002-01-16
|
I0666-1 |
R
|
Replacement of defective power supplies in E220R/E420R systems |
2001-07-24
|
I0570-3 |
R
|
Provide instructions and guidelines to CORRECTLY identify Ecache panic fault diagnosis. |
2000-07-07
|