Backplane/Centerplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 501-4799 [F] 5-Slot Centerplane n/a
Boot PROM
Socket Manufacturing
Part #
Patch
U3101 525-1387 [F] 103346
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
X2590A 501-6620 [F] 464MHz UltraSPARC II Module
(8MB Cache Blaze)
IBM Sombra Mirrored Data SRAM
IBM Mirrored Tag SRAM
501-5816 [F]
501-6623 1 [F] 464MHz UltraSPARC II Module
(8MB Cache Blaze)
Sony Espejo Mirrored SRAM
Sony Mirrored Tag SRAM
501-5798 [F] [S]
X2500A [S] 501-2941 [F] 167MHz UltraSPARC Module
(512KB Cache Blackbird)
n/a
X2510A [S] 501-2959 [F] 167MHz UltraSPARC Module
(1MB Cache Blackbird)
n/a
X2530A [S] 501-4178 [F] 250MHz UltraSPARC II Module
(1MB Cache Blackbird)
n/a
X2550A [S] 501-4836 [F] 250MHz UltraSPARC II Module
(4MB Cache Blackbird)
SRAM 100-5528
n/a
X2560A [S] 501-4363 [F] 336MHz UltraSPARC II Module
(4MB Cache Sapphire-Black)
n/a
X2570A [S] 501-4995 [F] 400MHz UltraSPARC II
(4MB Cache Sapphire-Black)
n/a
501-5425 [F] 400MHz UltraSPARC II
(4MB Cache Sapphire-Black)
n/a
501-5585 [F] 400MHz UltraSPARC II Module
(4MB Cache Sapphire-Black)
n/a
X2580A [S] 501-5235 [F] 400MHz UltraSPARC II Module
(8MB Cache Sapphire-Black)
n/a
501-5661 [F] 400MHz UltraSPARC II Module
(8MB Cache Sapphire-Black)
n/a
501-5762 [F] 400MHz UltraSPARC II Module
(8MB Cache Sapphire-Black)
n/a
X2580A 2 [S] 501-6624 [F] 400MHz UltraSPARC II Module
(8MB Cache Blaze)
Sony Espejo Mirrored Data SRAM
Sony Mirrored Tag SRAM
501-6009 [F] 
X2580A [S] 501-5838 [F] 400MHz UltraSPARC II Module
(8MB Cache Sapphire-Black)
IBM Sombra Mirrored Data SRAM
n/a
501-6008 [F] 400MHz UltraSPARC II Module
(8MB Cache Sapphire-Black)
IBM Sombra Mirrored Data SRAM
n/a
1 Replaced 501-5798 in February 2003
2 after April 2001
NOTE: UltraSPARC Module Installation
Communication
Option # Manufacturing
Part #
Description Previous
Part #
X1008A [S] 501-1931 [F] Serial Parallel Controller SBus (SPC/S) n/a
X1012A [S] 501-2603 [F] SunLink ISDN n/a
X1014A [S] 501-1932 [F] Token Ring Interface/SBus (TRI/S) n/a
X1019A [S] 501-1725 [F] High Speed Serial Interface/SBus (HSI/S) n/a
X1023A [S] 370-2715 [F] FDDI/S Single-Attach SBus (SAS) 4.0 n/a
X1024A [S] 370-2716 [F] FDDI/S Dual-Attach SBus (DAS) 4.0 n/a
X1025A [S] 370-2339 [F] FDDI/S Single-Attach SBus (SAS) 5.0 n/a
X1026A [S] 370-2340 [F] FDDI/S Dual-Attach SBus (DAS) 5.0 n/a
X1035A [S] 370-2811 [F] FDDI/P SAS Adapter PCI 1.0 n/a
X1036A [S] 370-2812 [F] FDDI/P DAS Adapter PCI 1.0 n/a
X1039A [S] 375-0001 [F] Token Ring Interface PCI (TRI/P) 1.0 n/a
X1040A [S] 370-2728 [F] High Speed Serial Interface PCI (HSI/P) 1.0 n/a
X1041A [S] 370-2810 [F] Serial Asynchronous Interface PCI (SAI/P) 1.0 n/a
X1050A [S] 501-2523 [F] SunATM-155/MFiber SBus 1.0 n/a
X1051A [S] 501-2665 [F] SunATM-155/UTP5 SBus 1.0 n/a
X1060A [S] 501-2794 [F] SunATM-155/MFiber SBus 2.X n/a
X1061A [S] 501-2795 [F] SunATM-155/UTP SBus 2.X n/a
X1064A [S] 501-2864 [F] SunATM-622/MFiber SBus 2.X n/a
X1066A [S] 501-3028 [F] SunATM-155/MFiber PCI 3.0 n/a
X1067A [S] 501-3027 [F] SunATM-155/UTP PCI 3.0 n/a
X1068A [S] 501-3029 [F] SunATM-622/MFiber PCI 3.0 n/a
X1070A [S] 370-3878 [F] HIPPI/P 1.0 High Performance Interface Board n/a
X1071A [S] 370-3878 [F] HIPPI/P 1.1 High Performance Interface Board n/a
X1080A [S] 370-4273 [F] Enterprise System Interface (ESI/P) n/a
X1133A [S] 375-0130 [F] Crypto Accelerator I n/a
X1142A [S] 370-3142 [F] FDDI/S Single-Attach SBus (SAS) 5.0/6.0 n/a
X1143A [S] 370-3143 [F] FDDI/S Dual-Attach SBus (DAS) 5.0/6.0 n/a
X1144A [S] 501-1932 [F] Token Ring Interface/SBus (TRI/S) 4.0 n/a
X1145A [S] 501-1725 [F] High Speed Serial Interface/SBus (HSI/S) 3.0 n/a
X1146A [S] 501-1931 [F] Serial Parallel Controller SBus (SPC/S) 3.0 n/a
X1147A [S] 501-2794 [F] SunATM-155/MFiber SBus 4.0 n/a
X1148A [S] 501-2795 [F] SunATM-155/UTP SBus 4.0 n/a
X1149A [S] 501-2864 [F] SunATM-622/MFiber SBus 4.0 n/a
X1152A [S] 370-2811 [F] FDDI/P SAS Adapter PCI 2.0 n/a
X1153A [S] 370-2812 [F] FDDI/P DAS Adapter PCI 2.0 n/a
X1154A [S] 375-0001 [F] Token Ring Interface PCI (TRI/P) 4.0 n/a
X1155A [S] 370-2728 [F] High Speed Serial Interface PCI (HSI/P) 2.0 n/a
X1156A [S] 370-2810 [F] Serial Asynchronous Interface PCI (SAI/P) 2.0 n/a
X1157A [S] 501-3028 [F] SunATM-155/MFiber PCI 4.0 n/a
X1158A [S] 501-3027 [F] SunATM-155/UTP PCI 4.0 n/a
X1159A [S] 501-3029 [F] SunATM-622/MFiber PCI 4.0 n/a
X2144A [S] 501-1932 [F] Token Ring Interface/SBus (TRI/S) 5.0 n/a
X2154A [S] 375-0073 [F] Token Ring Interface (TRI/P) 5.0 n/a
X2156A [S] 375-0100 [F] Serial Asynchronous Interface PCI (SAI/P) 3.0 n/a
Disks
Option # Manufacturing
Part #
Description Previous
Part #
X6709A [S] 540-3852 [F] 9.1GB - 7200 RPM FC-AL, Disk Assembly with 1 bracket, 1 shield, 1 of the following plates, and 1 disk: n/a
  • 340-4288
  • Plate
n/a
  • 340-5928
  • Plate
n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • 340-3462
  • Shield
n/a
  • Seagate ST19171FC [ST19171FCSUN9.1G]
    (9.1GB - 7200 RPM - FC-AL Disk)
n/a
  • 540-3025
  • 1.6" SPUD bracket
n/a
X6710A [S] 540-3869 [F] 9.1GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-4288
  • Plate
n/a
  • 340-5928
  • Plate
n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST39102FC [ST39102FSUN9.0G]
    (9.1GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST39103FC [ST39303FCSUN9.0G]
    (9.1GB - 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
X6711A [S] 540-3923 [F] 18.2GB - 7200 RPM FC-AL, Disk Assembly with 1 bracket, 1 disk, and 1 of the following plates: n/a
  • 340-4288
  • Plate
n/a
  • 340-5928
  • Plate
n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST118273FC [ST118273FSUN18G]
    (18.2GB - 7200 RPM - FC-AL Disk)
n/a
  • 540-3025
  • 1.6" SPUD bracket
n/a
X6720A [S] 540-4191 [F] 18.2GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-5928
  • Plate
n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST318203FC [ST318203FSUN18G]
    (18.2GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST318304FC [ST3183046SUN18G]
    (18.2GB - 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
X6724A [S] 540-4525 [F] 36.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST336704FC [ST336704FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST336605FC [ST336605FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST336607FC [ST336607FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
X6728A [S] 540-4673 [F] 18.2GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST318203FC [ST318203FSUN18G]
    (18.2GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST318304FC [ST3183046SUN18G]
    (18.2GB - 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
X1033A [S] 501-5019 [F] Sun FastEthernet PCI Adapter (FE/P) 2.0 n/a
X1034A [S] 501-5406 [F] Quad FastEthernet PCI (QFE/P) n/a
X1042A [S] 501-4302 [F] Sun Quad FastEthernet SBus (SQFE/S) 1.0 n/a
X1044A [S] 375-0002 [F] Gigabit Ethernet PCI (GBE/P) 1.0 n/a
X1045A [S] 375-0003 [F] Gigabit Ethernet SBus (GBE/S) 1.0 n/a
X1049A [S] 501-5443 [F] Sun Quad FastEthernet SBus (SQFE/S) 2.0 n/a
X1056A [S] 501-2655 [F] SunFastEthernet 1.0 Adapter n/a
X1058A [S] 501-2062 [F] SBus Quad Ethernet Controller (SQEC/S) n/a
X1059A [S] 501-2919 [F] SunFastEthernet Adapter 2.0 (Colossus Lite) n/a
X1140A [S] 501-4375 [F] Gigabit Ethernet SBus (GBE/S) 2.0 n/a
X1141A [S] 501-4373 [F] Gigabit Ethernet PCI (GBE/P) 2.0 n/a
X1150A [S] 501-5902 [F] Sun GigaSwift Ethernet UTP (Copper) n/a
X1151A [S] 501-5524 [F] Sun GigaSwift Ethernet MMF (Fiber) n/a
X3150A [S] 501-5902 [F] Sun GigaSwift Ethernet UTP (Copper) n/a
X3151A [S] 501-5524 [F] Sun GigaSwift Ethernet MMF (Fiber) n/a
X467A [S] 595-3780 [F] MII to AUI Converter n/a
Fibre Channel
Option # Manufacturing
Part #
Description Previous
Part #
X6731A 370-2303 [F] FC-AL SW-GBIC Module n/a
SG-XPCI1FC-QF2 [S] 375-3102 [F] 2Gb PCI Single FC Host Adapter n/a
SG-XPCI1FC-QL2 [S] 375-3383 [F] 2Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI2FC-QF2 [S] 375-3108 [F] 2Gb PCI/PCI-X Dual FC Host Adapter n/a
  • 240-4839
  • Low Profile Bracket,
n/a
X1057A [S] 501-2069 [F] SBus Optical Channel Host Adapter (SOCHA) n/a
X2652A [S] 501-4820 [F] FC-AL Interface Board Kit n/a
501-5144 [F] FC-AL Interface Board Kit n/a
X595A [S] 370-1426 [F] Fibre Channel Optical Module (FC/OM) n/a
X6727A [S] 375-3030 [F] PCI Dual FC Host Adapter+, L n/a
X6730A [S] 540-2989 FC-AL SBus Card (FC100/S) n/a
  • FC-AL SBus Host Adapter (FC100/S)
501-5202 [F] 
X6757A [S] 375-3048 [F] SBus Dual FC Network Adapter n/a
X6767A 3 [S] 375-3102 [F] 2Gb PCI Single FC Host Adapter n/a
X6768A 4 [S] 375-3108 [F] 2Gb PCI/PCI-X Dual FC Host Adapter n/a
  • 240-4839
  • Low Profile Bracket,
n/a
X6799A [S] 375-3019 5 [F] PCI Single FC Host Adapter n/a
3 X6767A changed to SG-XPCI1FC-QF2 in July 2003
4 X6768A changed to SG-XPCI2FC-QF2 in July 2003
5 375-3019 with SC connector is no longer available. The substitute adapter uses a smaller LC connector.
Graphics
Option # Manufacturing
Part #
Description Previous
Part #
X1085A [S] 501-3019 [F] SunVideo Board n/a
X3653A [S] 501-4127 [F] Creator Series 1 (FFB) 24-Bit Frame Buffer n/a
X3655A [S] 501-2955 [F] TurboGXplus 8-Bit Frame Buffer n/a
X3657A [S] 501-4173 [F] Creator3D Series 2 (FFB2) 24-Bit Frame Buffer n/a
X3667A [S] 540-3979 [F] Elite3D-m6 24-Bit Frame Buffer n/a
X3668A [S] 370-3753 [F] PGX32 8/24-Bit Color Frame Buffer n/a
X3671A [S] 501-4790 [F] Creator3D Series 3 (FFB2+) 24-Bit Frame Buffer n/a
X3768A [S] 370-4362 [F] PGX64 8/24-Bit Color Frame Buffer n/a
X7110A [S] 501-2922 [F] TurboGX 8-Bit Frame Buffer n/a
I/O
Option # Manufacturing
Part #
Description Previous
Part #
X2610A [S] 501-4287 [F] SBus I/O Board n/a
X2611A [S] 501-4266 [F] SBus I/O Board with SOC+ n/a
X2612A [S] 501-4883 [F] SBus I/O Board with SOC+ n/a
X2620A [S] 501-4288 [F] Graphics I/O Board 501-2749 [F]
X2622A [S] 501-4884 [F] Graphics I/O Board with SOC+ n/a
X2630A [S] 501-4325 [F] PCI I/O Board n/a
X2632A [S] 501-4926 [F] PCI I/O Board n/a
n/a 501-4128 [F] PCI I/O Riser Board (3.3V) n/a
n/a 501-4169 [F] PCI I/O Riser Board (5V) n/a
IDPROM
Socket Manufacturing
Part #
Component Type Host ID
U0205 (Clock), U2501 (I/O) 100-4007 48T59 NVRAM 80xxxxxx
Input Device
Option # Manufacturing
Part #
Description Previous
Part #
X485A [S] 370-1804 Color Video Camera (to add to X1085A) n/a
X487A [S] 595-3277 [F] SunVideo SBus Kit (X1085A + X485A) n/a
X495A [S] 370-1414 [F] SunMicrophone n/a
Memory
Option # Manufacturing
Part #
Description Previous
Part #
X6738A [S] 375-0087 [F] 32MB SBus Fast Write Cache n/a
X7021A [S] 64 MB (8 × 8MB DIMMs)
501-2652 [F] 8MB DIMM n/a
X7022A [S] 256 MB (8 × 32MB DIMMs)
501-2653 [F] 32MB DIMM n/a
X7023A [S] 1 GB (8 × 128MB DIMMs)
501-2654 [F] 128MB DIMM n/a
X7026A [S] 2 GB (8 × 256MB DIMMs)
501-5658 [F] 256MB DIMM n/a
n/a 501-6901 [F] 256MB DIMM (Dataram) n/a
n/a 501-6902 [F] 256MB DIMM (Hyundai) n/a
Miscellaneous
Option # Manufacturing
Part #
Description Previous
Part #
X1030A [S] 501-2367 [F] PCMCIA Interface/SBus Card n/a
n/a 595-4182 E3x00 Floor Mount Brackets n/a
Power
Option # Manufacturing
Part #
Description Previous
Part #
X954A [S] 300-1444 [F] FDK PEX690-31 300 Watt Power/Cooling Module (Type A146) n/a
X9689A [S] 300-1358 [F] FDK PEX750-30 195 Watt Peripheral Power Supply (Type A129) Front Unit n/a
n/a 300-1400 [F] FDK PEX705-40 184 Watt Peripheral Power Supply (Type A109) Rear Unit n/a
Removable Media
Option # Manufacturing
Part #
Description Previous
Part #
X6104A [S] 370-2202 [F] 2.5GB 1/4" Tape Drive (Medium Grey Bezel) n/a
X6213A [S] 370-2882 [F] 7-14GB 8 mm Tape Drive (Medium Grey Bezel) n/a
X6238A [S] 370-2184 [F] 20-40GB 8 mm Tape Drive (Medium Grey Bezel) n/a
X6259A [S] 370-2177 [F] 4-8GB 4 mm DDS-2 Tape Drive (Medium Grey Bezel) n/a
X6283A [S] 370-2376 [F] 12-24GB 4 mm DDS-3 Tape Drive (Medium Grey Bezel) n/a
X6296A [S] 390-0027 [F] 20-40GB 4 mm DDS-4 Tape Drive (Medium Grey Bezel) n/a
n/a 370-3416 6 [F] SunCD 32 CD-ROM n/a
n/a 390-0025 [F] 10X DVD-ROM Drive n/a
6 Standard configuration until December 2000
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
X1018A [S] 501-2739 [F] Single-Ended Fast/Wide SCSI/FastEthernet (SunSwift/S) n/a
X1032A [S] 501-5656 [F] Single-Ended Ultra/Wide SCSI/FastEthernet (SunSwift PCI) n/a
X1052A [S] 501-1902 [F] Fast Differential SCSI-2/Buffered Ethernet (DSBE/S) n/a
X1053A [S] 501-2981 [F] Fast SCSI-2/Buffered Ethernet (FSBE/S) 501-2015 [F]
X1062A [S] 370-1704 [F] Differential Fast/Wide SCSI-2 Host Adapter (DWIS/S) n/a
X1063A [S] 370-1703 [F] Single-Ended Fast/Wide SCSI-2 Host Adapter (SWIS/S) n/a
X1065A [S] 370-2443 [F] Differential Ultra/Wide SCSI Host Adapter (UDWIS/S) (HVD) n/a
Switch/Hub
Option # Manufacturing
Part #
Description Previous
Part #
X6746A [S] Redundant FC 8-port Switch Option (two 8-port switches)
540-4372 [F] StorEdge Network FC Switch-8 n/a
System Board
Option # Manufacturing
Part #
Description Previous
Part #
X2600A [S] 501-2976 [F] CPU/Memory Board - 0MB FRU w/o Module, 83MHz Gigaplane (2MB cache per module) n/a
X2601A [S] 501-4312 [F] CPU/Memory Board - 0MB FRU w/o Module, 83MHz Gigaplane (8MB cache per module) n/a
X2602A [S] 501-4882 [F] CPU/Memory Board - 0MB FRU w/o Module, 83/90/100MHz Gigaplane n/a
n/a 501-4946 [F] Clock Board - 83/90/100MHz Gigaplane
(1:2, 1:3, 1:4 clock ratios)
n/a
n/a 501-5365 [F] Clock Board - 83/90/100MHz Gigaplane
(1:2, 1:3, 1:4, 1:5, 1:6 clock ratios)
n/a

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

Sun Enterprise 3500 Exploded View
Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
1 540-3531 Upper Chassis Assembly
2 540-3743 Lower Base Assembly
-
  • 240-1806
  • Caster
3 501-2599 [F] LED Board
4 530-2148 [F] Keyswitch Cable Assembly
5 540-3815 Peripheral Power Supply Filler Panel
6 540-3566 [F] 3-Fan Tray Assembly with Fan 370-3321
7 540-3501 Front Door Assembly
8 540-2851 Front Bezel with Plastic Label Cover 330-1973
9 340-3312 Peripheral Tray
10 530-2226 [F] Backplane to LED PCB Cable
11 530-2381 [F] Peripheral Tray SCSI Cable, 93.5 cm
12 530-2221 [F] Peripheral Tray DC Cable (×2)
13 330-2002 Top Cover
14 540-2593 [F] Power/Cooling Module Filler Panel
15 540-2757 [F] Auxiliary Fan Assembly
15 540-4053 [F] Auxiliary Fan Assembly
16 330-1993 Side Panel
NS 240-2291 Door Catch
NS 262-4171 E3500 Nameplate
NS 330-1939 Filler Panel
NS 330-2014 [F] AC Power Key / Door Key,
NS 340-3304 Peripheral Mounting Bracket
NS 340-3341 Filler Panel Bracket
NS 530-1871 [F] RJ45 to RJ45 Cable, 4M
NS 530-2093 [F] Shielded RJ45 to RJ45 Cable, 4M
NS 540-2592 [F] Board Slot Filler Panel
NS 540-3795 [F] Fiber Channel Interface Board Slot Filler Panel