Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra 20 Server - Full Components List

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Batteries
Option # Manufacturing
Part #
Description Previous
Part #
n/a 150-2850 [F] 3V Lithium Battery BR1632 / CR1632, n/a
Boot PROM
Socket Manufacturing
Part #
Patch
U2103 525-1807 111292
U2103 525-1899 111292
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
X6988A [S] 501-6248 [F] 750MHz UltraSPARC III Module (DC Model) n/a
X6990A [S] 501-5675 [F] 750MHz UltraSPARC III Module (AC Model) n/a
X7009A [S] 501-6747 [F] 900MHz UltraSPARC III Cu Module
(501-6002 screened for processor flatness)
n/a
X7310A [S] 501-6750 [F] 1200MHz UltraSPARC III Cu Module
(501-6690 screened for processor flatness)
501-6690 [F]
n/a 501-6002 [F] 900MHz UltraSPARC III Cu Module n/a
n/a 501-6485 [F] 1200MHz UltraSPARC III Cu Module n/a
n/a 501-6690 [F] 1200MHz UltraSPARC III Cu Module n/a
n/a 501-6745 [F] 1200MHz UltraSPARC III Cu Module
(501-6485 screened for processor flatness)
501-6485 [F]
n/a 501-6805 [F] 1200MHz UltraSPARC III Cu Module n/a
Cables
Option # Manufacturing
Part #
Description Previous
Part #
n/a 530-3032 [C] Power Cable n/a
n/a 560-2631 [F] Power Cable Kit n/a
  • 530-3026
  • Removable Media Power Cable
n/a
  • 530-3027
  • System Board to PDB Switch Cable
n/a
  • 530-3028
  • System Board to PDB Sense Cable
n/a
  • 530-3029
  • FC-AL Backplane to PDB Power Cable
n/a
  • 530-3030
  • FC-AL Backplane to PDB I2C Cable
n/a
n/a 560-2632 [F] Data Cable Kit n/a
  • 530-3031
  • SCCR to System Board to PDB Cable
n/a
  • 530-3033
  • Alarm Module to PDB to LED Board Cable
n/a
  • 530-3065
  • Removable Media SCSI Cable with 50-Pin to 68-Pin Adapter
n/a
Card/Reader
Option # Manufacturing
Part #
Description Previous
Part #
n/a 370-4435 System Configuration Card n/a
n/a 370-5155 [F] System Configuration Card, n/a
n/a 501-5965 [F] System Configuration Card Reader n/a
Communication
Option # Manufacturing
Part #
Description Previous
Part #
X1133A [S] 375-0130 [F] Crypto Accelerator I n/a
X1155A [S] 370-2728 High Speed Serial Interface PCI (HSI/P) 2.0 n/a
X1157A [S] 501-3028 [F] SunATM-155/MFiber PCI 4.0 n/a
X1158A [S] 501-3027 [F] SunATM-155/UTP PCI 4.0 n/a
X2156A [S] 375-0100 [F] Serial Asynchronous Interface PCI (SAI/P) 3.0 n/a
X4011A [S] 501-6039 [F] Crypto Accelerator 4000 UTP (copper) n/a
X4012A [S] 501-6040 [C] Crypto Accelerator 4000 MMF (fiber) n/a
X4111A [S] 501-6039 [F] Crypto Accelerator 4000 UTP (copper) n/a
X4112A [S] 501-6040 [C] Crypto Accelerator 4000 MMF (fiber) n/a
X6762A [S] 375-3089 [F] Crypto Accelerator 1000 n/a
X7087A [S] 501-6543 [F] Alarm/LOMlite2 Module (1200MHz) n/a
n/a 501-5893 [F] Alarm/LOMlite2 Module (750MHz/900MHz) n/a
Disks
Option # Manufacturing
Part #
Description Previous
Part #
X6724A [S] 540-4525 [F] 36.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST336704FC [ST336704FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST336605FC [ST336605FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST336607FC [ST336607FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
X6805A [S] 540-6604 3 [F] [S] 73.4GB - 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks, 540-5408 2 [F]
  • 341-1986 [S]
  • Plate,
n/a
  • Fujitsu MAW3073FC [MAW3073FCSUN73G]
    (73.4GB - 10000 RPM - FC-AL Disk),
n/a
  • Hitachi HUS1073FA [HUS1073FASUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk),
n/a
  • Seagate ST373207FC [ST373207FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk),
n/a
  • 1" SPUD Bracket,
n/a
X6819A [S] 540-5698 [F] 36.4GB - 10000 RPM FC-AL, Disk Assembly (NEBS) with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST336704FC [ST336704FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST336605FC [ST336605FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST336607FC [ST336607FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Hitachi DK32EJ-36FC [DK32EJ72FSUN72G]
    (36.4GB 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
X6855A [S] 540-5694 [F] 73.4GB - 10000 RPM FC-AL, Disk Assembly (NEBS) with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST373405FC [ST373405FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST373307FC [ST373307FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Fujitsu MAP3735FC [MAP3735F SUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Hitachi DK32EJ-72FC [DK32EJ72FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
n/a 540-5408 1 [F] 73.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST373405FC [ST373405FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Fujitsu MAN3735FC [MAN3735F SUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST373307FC [ST373307FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Fujitsu MAP3735FC [MAP3735F SUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Hitachi DK32EJ-72FC [DK32EJ72FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST373207FC [ST373207FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Fujitsu MAT3073FC [MAT3073F SUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Hitachi HUS1073FA [HUS1073FASUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
1 Effective 27-Jan-2006, this assembly was replaced by 540-6604 in option X6805A.
2 Effective 27-Jan-2006, this assembly was replaced by 540-6604 in option X6805A.
3 Effective 27-Jan-2006, this assembly ships with option X6805A.
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
X1033A [S] 501-5019 [F] Sun FastEthernet PCI Adapter (FE/P) 2.0 n/a
X1034A [S] 501-5406 [F] Quad FastEthernet PCI (QFE/P) n/a
X1141A [S] 501-4373 [F] Gigabit Ethernet PCI (GBE/P) 2.0 n/a
X1150A [S] 501-5902 [F] Sun GigaSwift Ethernet UTP (Copper) n/a
X1151A [S] 501-5524 [F] Sun GigaSwift Ethernet MMF (Fiber) n/a
X3150A [S] 501-5902 [F] Sun GigaSwift Ethernet UTP (Copper) n/a
X3151A [S] 501-5524 [F] Sun GigaSwift Ethernet MMF (Fiber) n/a
X4150A [S] 501-6719 [F] GigaSwift Ethernet UTP (GCS) n/a
X4151A [S] 501-6762 [F] GigaSwift Ethernet MMF (GFS) n/a
X4444A 4 [S] 501-6522 [F] Quad GigaSwift Ethernet UTP (QGE) n/a
X4445A [S] 501-6738 [F] Quad GigaSwift PCI-X Ethernet (QGE-X), n/a
4 If replacing X4444A with X4445A (same driver but different chip set), a reconfigure boot is required. See Problem article 1003454.1.
Fibre Channel
Option # Manufacturing
Part #
Description Previous
Part #
SG-XPCI1FC-QF4 Price 375-3354 [F] 4Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI2FC-QF4 Price 375-3294 [F] 4Gb PCI-X Dual FC Host Adapter, n/a
SG-XPCI1FC-EM2 [S] 375-3304 [F] 2Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI1FC-QL2 [S] 375-3383 [F] 2Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI2FC-EM2 [S] 375-3305 [F] 2Gb PCI-X Dual FC Host Adapter, n/a
SG-XPCI2FC-QF2-Z [S] 375-3363 [F] 2Gb PCI/PCI-X Dual FC Host Adapter, n/a
  • 240-4839
  • Low Profile Bracket,
n/a
X6727A [S] 375-3030 [F] PCI Dual FC Host Adapter+, L n/a
X6799A [S] 375-3019 5 [F] PCI Single FC Host Adapter n/a
n/a 540-4794 [F] 2-Slot FC-AL Disk Backplane n/a
5 375-3019 with SC connector is no longer available. The substitute adapter uses a smaller LC connector.
Graphics
Option # Manufacturing
Part #
Description Previous
Part #
X3685A [S] 375-3069 [F] XVR-500 Graphics Accelerator n/a
X3780A [S] 375-3153 [F] XVR-600 Graphics Accelerator n/a
Memory
Option # Manufacturing
Part #
Description Previous
Part #
X7056A 4 GB (4 × 1GB SDRAM DIMMs)
501-7386 [F] 1GB SDRAM DIMM, L 501-6109 [F]
X7050A [S] 512MB (4 × 128MB SDRAM DIMMs)
501-4489 [F] 128MB SDRAM DIMM n/a
X7051A [S] 2 GB (4 × 512MB SDRAM DIMMs)
501-7385 [F] 512MB SDRAM DIMM, L 501-5030 [F] 
X7052A [S] 4 GB (4 × 1GB SDRAM DIMMs)
501-5031 [F] 1GB SDRAM DIMM n/a
X7053A [S] 1 GB (4 × 256MB SDRAM DIMMs)
501-5401 [F] 256MB SDRAM DIMM 540-5084
X7061A 11 [S] 1 GB (4 × 256MB SDRAM DIMMs)
501-6175 [F] 256MB SDRAM DIMM CR1/LC1 n/a
X7062A 12 [S] 2 GB (4 × 512MB SDRAM DIMMs)
501-6174 [F] 512MB SDRAM DIMM CR1/LC1 n/a
n/a 501-5030 [F] 512MB SDRAM DIMM 540-5085
n/a 501-6109 [F] 1GB SDRAM DIMM n/a
n/a 540-5086 [F] 1GB SDRAM DIMM n/a
n/a F511-1030 7 [F] Package of 25 × 512MB SDRAM DIMMs n/a
  • 512MB SDRAM DIMM, L
501-5030 [F] 
n/a F511-1031 9 [F] Package of 25 × 1GB SDRAM DIMMs n/a
  • 1GB SDRAM DIMM, L
501-6109 [F]
7 See FAB article1000920 (formerly 201233) for details.
9 See FAB article1000920.1 (formerly 201233) for details.
11 For 1200MHz models only
12 For 1200MHz models only
Miscellaneous
Option # Manufacturing
Part #
Description Previous
Part #
X949A [S] 595-5302 Wago DC Connector Set, n/a
  • 130-4361
  • DC Connector,
n/a
  • 230-1708
  • DC Connector Strain Relief
n/a
  • 230-1711
  • DC Connector Opening Lever
n/a
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-1496 [F] AC Input Power Supply Type A161 n/a
n/a 300-1497 [F] DC Input Power Supply Type D139 n/a
n/a 540-4795 [F] Power Distribution Assembly n/a
  • Power Distribution Board
n/a
Rack
Option # Manufacturing
Part #
Description Previous
Part #
X6845A [S] 595-6721 Netra 20 Rack Mount Kit for Sun Rack 900 n/a
X6902A [S] 595-4630 23" Rack Mount Kit n/a
X6903A [S] 595-4631 24" Rack Mount Kit n/a
X6904A [S] 595-4632 600 mm Rack Mount Kit n/a
X7099A [S] 595-5832 19" Slide Adapter Kit n/a
Removable Media
Option # Manufacturing
Part #
Description Previous
Part #
X6168A [S] 390-0025 [F] 10X DVD-ROM Drive n/a
X6295A [S] 390-0028 [F] 20-40GB 4 mm DDS-4 Tape Drive (Medium Grey Bezel) n/a
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
SGXPCI2SCSILM320-Z Price 375-3365 13 [F] PCI Dual Ultra320 SCSI Adapter, L n/a
SG-XPCI2SCSI-LM320 [S] 375-3191 [F] PCI/PCI-X Dual Ultra320 SCSI Adapter n/a
X1032A [S] 501-5656 [F] Single-Ended Ultra/Wide SCSI/FastEthernet (SunSwift PCI) n/a
X2222A [S] 501-5727 [F] Dual FastEthernet / Dual SCSI PCI Adapter n/a
X4422A [S] 501-6635 [F] Dual GigabitEthernet / Dual SCSI PCI Adapter n/a
X6540A [S] 375-0005 [F] Dual Single-Ended Ultra/Wide SCSI (PCI) n/a
X6541A [S] 375-0006 [F] Dual Differential Ultra/Wide SCSI (UDWIS/P)(HVD) n/a
X6542A [S] 375-0078 [F] SCSI RAID Controller (SRC/P) n/a
X6758A [S] 375-3057 14 [F] PCI Dual Ultra3 SCSI Host Adapter (LVD) n/a
13 Ultra320 SCSI HBA (375-3365-01 REV 52) FCode 1.13 fails to work on all Sun Platforms, replace it with 375-3365-02 REV 50. See Problem article 1013105.1.
14 The necessary drivers (SUNWqus, SUNWqusu, SUNWqusx, & SUNWqusux) and patches for this product are not included in Solaris 8 or 9, but must be downloaded. Please see How To article 1018123.1 for details.
Switch/Hub
Option # Manufacturing
Part #
Description Previous
Part #
X6746A [S] Redundant FC 8-port Switch Option (two 8-port switches)
540-4372 [F] StorEdge Network FC Switch-8 n/a
System Board
Option # Manufacturing
Part #
Description Previous
Part #
n/a 501-5938 [F] 0MB FRU (SCHIZO 2.2) n/a
n/a 501-6230 16 [F] 0MB FRU (SCHIZO >=2.2) n/a
n/a 501-6560 [F] 0MB FRU (SCHIZO 2.5) n/a
15 501-6230-07 is not compatible with Netra 20.
16 501-6230-07 is not compatible with Netra 20.
17 501-6230-07 is not compatible with Netra 20.

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

Netra 20 Exploded View
Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
1 540-4891 Top Cover
2-3 540-4696 [F] Shroud/Shroud Cover Assembly
2
  • 540-4137
  • CPU Module Shroud Cover Assembly
2
    • 330-2706
    • CPU Module Shroud Cover
3
  • 540-4136
  • System Board Shroud Assembly
3
    • 330-2705
    • System Board Shroud
4 501-5915 [F] LED Card and Switch Assembly
5 370-4360 [F] Fan Assembly, 127mm (CPU)
6 540-5023 [F] Fan Assembly, 80mm (PSU)
7 540-4745 Chassis Assembly
8 540-4892 Removable Media Assembly
9 595-6161 Air Filter Pack, Option X7216A [S]
10 595-6162 Front Fascia Kit, Option X7217A [S]
NS 330-3257 DAT Panel
NS 330-3258 CD Panel
NS 330-3272 Air Filter (obsolete)
NS 340-7006 Air Filter Frame
NS 340-7023 DAT/CD-ROM Drive Filler Panel
NS 370-3273 PCI Filler Panel
NS 540-4869 Front Bezel
NS 540-4995 Disk Drive Filler Panel
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback