Sun Fire V490 - Full Components List
|
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
|
|
|
Batteries
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
150-2850 [F]
|
3V Lithium Battery BR1632 / CR1632, |
n/a |
Cables
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X312L |
Localized Power Cord Kit - Continental Europe, |
180-1993
[C]
|
IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, |
n/a |
X314L |
Localized Power Cord Kit - Swiss, |
180-1994
[C]
|
IEC 320 C13 to SEV 1011 - 10A/250V 2.5M Black, |
n/a |
X317L |
Localized Power Cord Kit - U.K., |
180-1997
[C]
|
IEC 320 C13 to BS 1363 - 10A/250V 2.5M Black, |
n/a |
X320A Price
|
Localized Power Cord Kit - North America/Asia, |
180-2164
[C]
|
IEC 320 C13 to NEMA 6-15P - 10A/250V 2.0M Black, |
530-1351
[C]
|
X332T |
International Power Cord Kit, |
180-2071
[C]
[S]
|
Blue 16A IEC 309 to IEC 320 C13 International 4.0M, |
n/a |
X333A-25-10-IL |
Localized Power Cord Kit Israel, |
180-2130
[C]
|
IEC 320 C13 to SI-32, 10A/250V, 2.5M, Black, |
n/a |
X340L Price
|
Power Kit for North America, L6-20 20A Twist Lock Plug, |
180-2070
[C]
|
NEMA L6-20P to IEC 320 C13 - 4.0M, |
n/a |
X383L |
Localized Power Cord Kit - Danish, |
180-1995
[C]
|
IEC 320 C13 to Asfnit 107 - 10A/250V 2.5M Black, |
530-1819
[C]
|
X384L |
Localized Power Cord Kit - Italian, |
180-1996
[C]
|
IEC 320 C13 to CEI 23-16/VII - 10A/250V 2.5M Black, |
n/a |
X386L |
Localized Power Cord Kit - Australian, |
180-1998
[C]
[S]
|
IEC 320 C13 to AS 3112 - 10A/250V 2.5M Black, |
n/a |
X9715A |
537-1020
[F]
|
Fibre Optical Cable SC/SC, 5M |
n/a |
X973A |
537-1004
[F]
|
Fibre Channel Optical Cable 50/125 Multimode, 2M |
n/a |
X978A |
537-1006
[F]
|
Fibre Channel Optical Cable 50/125 Multimode, 15M |
n/a |
X336L
[S]
|
U.S. Power Cords 4-Pack, |
180-2070
[C]
|
NEMA L6-20P to IEC 320 C13 - 4.0M, |
n/a |
X337L
[S]
|
International Power Cords 4-Pack, |
180-2071
[C]
[S]
|
Blue 16A IEC 309 to IEC 320 C13 International 4.0M, |
n/a |
X338L
[S]
|
U.S. Watertight Power Cords 4-Pack, |
180-2072
[C]
|
Blue 20A Watertight IEC 309 to IEC 320 C13, 4.0M, |
n/a |
X339L
[S]
|
International Watertight Power Cords 4-Pack, |
180-2073
[C]
[S]
|
Blue 16A Watertight IEC 309 to IEC 320 C13 4.0M, |
n/a |
X3830A
[S]
|
530-2454
[F]
|
External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 4M |
n/a |
X3831A
[S]
|
530-2455
[F]
|
External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 10M |
n/a |
X3872A
[S]
|
130-3034
[F]
|
HD15F to DB13W3M Adapter |
n/a |
X470A
[S]
|
530-2357
[F]
|
Video Connector Adapter, 13W3F to HD15M |
n/a |
X9280A
[S]
|
530-3387 [C]
|
4X SFF8470 to 12X SFF8470 InfiniBand Cable, 2 Meter |
n/a |
X9281A
[S]
|
530-3386 [C]
|
4X SFF8470 to 12X SFF8470 InfiniBand Cable, 5 Meter |
n/a |
X9713A
[S]
|
530-3018 [F]
|
Loop-B FC-AL Cable |
n/a |
n/a |
530-1351
[C]
|
IEC 320 C13 to NEMA 6-15 - 10A/250V 2.0M Black, |
n/a |
n/a |
530-1819
[C]
|
Localized Power Cord Kit - Danish |
n/a |
n/a |
530-3013 [F]
|
FC-AL Backplane Power Cable |
n/a |
n/a |
530-3069 [F]
|
FC-AL Backplane Data Cable |
n/a |
n/a |
540-5064 [F]
|
Front Fan Tray Cable w/ Bracket 340-7241 |
n/a |
Communication
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X1355A-2 Price
|
371-0982 |
2M, 80-Pin, 4-Port, DB37, RS449 Breakout Cable, |
n/a |
375-3296
[F]
|
Quad Port High Speed Serial Interface PCI-X (HSI/U), |
n/a |
X1074A 3
[S]
|
370-3868
[F]
|
SCI Adapter (SCI/P) |
n/a |
X1155A
[S]
|
370-2728
[F]
|
High Speed Serial Interface PCI (HSI/P) 2.0 |
n/a |
X1157A
[S]
|
501-3028
[F]
|
SunATM-155/MFiber PCI 4.0 |
n/a |
X1233A
[S]
|
375-3259 4
[C]
|
Dual Port 4x InfiniBand Host Channel Adapter |
n/a |
X1333A-4
[S]
|
375-3418
[F]
|
Infiniband PCI-X Card, L |
n/a |
X2156A
[S]
|
375-0100
[F]
|
Serial Asynchronous Interface PCI (SAI/P) 3.0 |
n/a |
X4011A
[S]
|
501-6039
[F]
|
Crypto Accelerator 4000 UTP (copper) |
n/a |
X4012A
[S]
|
501-6040
[F]
|
Crypto Accelerator 4000 MMF (fiber) |
n/a |
X4111A
[S]
|
501-6039
[F]
|
Crypto Accelerator 4000 UTP (copper) |
n/a |
X4112A
[S]
|
501-6040
[F]
|
Crypto Accelerator 4000 MMF (fiber) |
n/a |
X6762A
[S]
|
375-3089
[F]
|
Crypto Accelerator 1000 |
n/a |
n/a |
501-6767
[F]
|
Advanced Lights Out Manager Plus Card |
n/a |
3 This option requires a pair of SCI cables: order two of option X3901A, X3903A, or X3904A. Option X3895A is needed for more than two nodes.
4 Infiniband Host Channel Adapter includes no cables, so cable option 9280 or 9281
should be ordered with card.
|
Disks
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X6724A
[S]
|
540-4525 [F]
|
36.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: |
n/a |
|
|
n/a |
|
|
n/a |
|
- Seagate ST336704FC [ST336704FSUN36G]
(36.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Seagate ST336605FC [ST336605FSUN36G]
(36.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Seagate ST336607FC [ST336607FSUN36G]
(36.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
|
n/a |
X6805A
[S]
|
540-6604 9
[F]
|
73.4GB - 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks, |
540-5408 8
[F]
|
|
|
n/a |
|
- Fujitsu MAW3073FC [MAW3073FCSUN73G]
(73.4GB - 10000 RPM - FC-AL Disk),
|
n/a |
|
- Hitachi HUS1073FA [HUS1073FASUN72G]
(73.4GB - 10000 RPM - FC-AL Disk),
|
n/a |
|
- Seagate ST373207FC [ST373207FSUN72G]
(73.4GB - 10000 RPM - FC-AL Disk),
|
n/a |
|
|
n/a |
XRA-FC1CB-146G10K
[S]
|
540-6605 11
[F]
|
146GB - 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks, |
540-5459 10
[F]
|
|
|
n/a |
|
- Fujitsu MAW3147FC [MAW3147FCSUN146G]
(146GB - 10000 RPM - FC-AL Disk),
|
n/a |
|
- Hitachi HUS1014FA [HUS1014FASUN146G]
(146GB - 10000 RPM - FC-AL Disk),
|
n/a |
|
- Seagate ST3146707FC [ST314670FSUN146G]
(146GB - 10000 RPM - FC-AL Disk),
|
n/a |
|
|
n/a |
XRA-FC1CB-146G15KZ
[S]
|
540-6487 [F]
|
146GB - 15000 RPM FC-AL, Disk Assembly with one of the following disks:, L
|
n/a |
|
|
n/a |
|
- Seagate ST3146854FC [ST314685FSUN146G]
(146GB - 15000 RPM - FC-AL Disk),
|
n/a |
|
- Fujitsu MAX3147FC [MAX3147FCSUN146G]
(146GB - 15000 RPM - FC-AL Disk),
|
n/a |
|
- Seagate ST3146855FC [ST314655FSUN146G]
(146GB - 15000 RPM - FC-AL Disk),
|
n/a |
|
- Hitachi HUS153014VLF400 [HUS1514FBSUN146G]
(146.8GB - 15000 RPM - FC-AL Disk),
|
n/a |
|
|
n/a |
n/a |
540-5408 5
[F]
|
73.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: |
n/a |
|
|
n/a |
|
|
n/a |
|
- Seagate ST373405FC [ST373405FSUN72G]
(73.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Fujitsu MAN3735FC [MAN3735F SUN72G]
(73.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Seagate ST373307FC [ST373307FSUN72G]
(73.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Fujitsu MAP3735FC [MAP3735F SUN72G]
(73.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Hitachi DK32EJ-72FC [DK32EJ72FSUN72G]
(73.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Seagate ST373207FC [ST373207FSUN72G]
(73.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Fujitsu MAT3073FC [MAT3073F SUN72G]
(73.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Hitachi HUS1073FA [HUS1073FASUN72G]
(73.4GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
|
n/a |
n/a |
540-5459 7
[F]
|
146GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: |
n/a |
|
|
n/a |
|
|
n/a |
|
- Seagate ST3146807FC [ST314680FSUN146G]
(146GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Fujitsu MAP3147FC [MAP3147F SUN146G]
(146.8GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Hitachi DK32EJ-14FC [DK32EJ14FSUN146G]
(146GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Seagate ST3146707FC [ST314670FSUN146G]
(146GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Fujitsu MAT3147FC [MAT3147F SUN146G]
(146GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Hitachi HUS1014FA [HUS1014FASUN146G]
(146GB - 10000 RPM - FC-AL Disk)
|
n/a |
|
- Fujitsu MAW3147FC [MAW3147FCSUN146G]
(146GB - 10000 RPM - FC-AL Disk),
|
n/a |
|
- Hitachi HUS1014FA [HUS1014FASUN146G]
(146GB - 10000 RPM - FC-AL Disk),
|
n/a |
|
- Seagate ST3146707FC [ST314670FSUN146G]
(146GB - 10000 RPM - FC-AL Disk),
|
n/a |
|
|
n/a |
5 Effective 27-Jan-2006, this assembly was replaced by 540-6604 in option X6805A.
6 Effective 27-Jan-2006, this assembly ships with option XRA-FC1CB-146G10K.
7 Effective 27-Jan-2006, this assembly was replaced by 540-6605 in option XRA-FC1CB-146G10K.
8 Effective 27-Jan-2006, this assembly was replaced by 540-6604 in option X6805A.
9 Effective 27-Jan-2006, this assembly ships with option X6805A.
10 Effective 27-Jan-2006, this assembly was replaced by 540-6605 in option XRA-FC1CB-146G10K.
11 Effective 27-Jan-2006, this assembly ships with option XRA-FC1CB-146G10K.
|
Ethernet
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X5558A Price
|
375-3301
[C]
|
10Gb/sec XFP Optical Transceiver Short Range (SR), L |
n/a |
X5560A-Z Price
|
375-3495
[C]
|
10Gb/sec XFP Optical Transceiver Long Range (LR), |
n/a |
X7285A Price
|
371-0911
[F]
|
Low Profile PCI-X Dual Gigabit Ethernet UTP, |
n/a |
4455A
[S]
|
10Gb PCI-X Ethernet Adapter w/ Transceiver (low-profile brackets) |
375-3301
[C]
|
10Gb/sec XFP Optical Transceiver Short Range (SR), L |
n/a |
501-7163
|
10Gb/sec PCI-X Ethernet Adapter |
n/a |
|
- Bracket Low-Profile 10Gb PCI-X Ethernet,
|
n/a |
4455A-4
[S]
|
375-3301
[C]
|
10Gb/sec XFP Optical Transceiver Short Range (SR), L |
n/a |
501-7414
|
10Gb/sec PCI-X Ethernet Adapter, |
n/a |
|
- Bracket Low-Profile 10Gb PCI-X Ethernet,
|
n/a |
4466A
[S]
|
375-3361
[C]
|
XFP Optical PCI-X Transceiver Single Mode Fibre, L |
n/a |
501-7414
|
10Gb/sec PCI-X Ethernet Adapter, |
n/a |
|
- Bracket Low-Profile 10Gb PCI-X Ethernet,
|
n/a |
5544A
[S]
|
10Gb PCI-X Ethernet Adapter w/ Transceiver (standard brackets) |
375-3301
[C]
|
10Gb/sec XFP Optical Transceiver Short Range (SR), L |
n/a |
501-7036
[C]
|
10Gb/sec PCI-X Ethernet Adapter |
n/a |
|
- Bracket Standard 10Gb PCI-X Ethernet,
|
n/a |
5544A-4
[S]
|
375-3301
[C]
|
10Gb/sec XFP Optical Transceiver Short Range (SR), L |
n/a |
501-7413
[C]
|
10Gb PCI-X Ethernet Adapter, |
n/a |
|
- Bracket Standard 10Gb PCI-X Ethernet,
|
n/a |
|
- Bracket Low-Profile 10Gb PCI-X Ethernet,
|
n/a |
6644A
[S]
|
375-3361
[C]
|
XFP Optical PCI-X Transceiver Single Mode Fibre, L |
n/a |
501-7413
[C]
|
10Gb PCI-X Ethernet Adapter, |
n/a |
|
- Bracket Standard 10Gb PCI-X Ethernet,
|
n/a |
|
- Bracket Low-Profile 10Gb PCI-X Ethernet,
|
n/a |
X1033A
[S]
|
501-5019
[F]
|
Sun FastEthernet PCI Adapter (FE/P) 2.0 |
n/a |
X1034A
[S]
|
501-5406
[F]
|
Quad FastEthernet PCI (QFE/P) |
n/a |
X1141A
[S]
|
501-4373
[F]
|
Gigabit Ethernet PCI (GBE/P) 2.0 |
n/a |
X1150A
[S]
|
501-5902
[F]
|
Sun GigaSwift Ethernet UTP (Copper) |
n/a |
X1151A
[S]
|
501-5524
[F]
|
Sun GigaSwift Ethernet MMF (Fiber) |
n/a |
X3150A
[S]
|
501-5902
[F]
|
Sun GigaSwift Ethernet UTP (Copper) |
n/a |
X3151A
[S]
|
501-5524
[F]
|
Sun GigaSwift Ethernet MMF (Fiber) |
n/a |
X4150A
[S]
|
501-6719
[F]
|
GigaSwift Ethernet UTP (GCS) |
n/a |
X4151A
[S]
|
501-6762
[F]
|
GigaSwift Ethernet MMF (GFS) |
n/a |
X4444A 12
[S]
|
501-6522
[F]
|
Quad GigaSwift Ethernet UTP (QGE) |
n/a |
X4445A
[S]
|
501-6738
[F]
|
Quad GigaSwift PCI-X Ethernet (QGE-X), |
n/a |
X5544A 13
[S]
|
10Gb PCI-X Ethernet Adapter, no transceiver |
370-7792 |
Bracket Low-Profile 10Gb PCI-X Ethernet, |
n/a |
501-7036
[C]
|
10Gb/sec PCI-X Ethernet Adapter |
n/a |
|
- Bracket Standard 10Gb PCI-X Ethernet,
|
n/a |
X5544A-4
[S]
|
10Gb PCI-X Ethernet Adapter, no transceiver, |
501-7413
[C]
|
10Gb PCI-X Ethernet Adapter, |
n/a |
|
- Bracket Standard 10Gb PCI-X Ethernet,
|
n/a |
|
- Bracket Low-Profile 10Gb PCI-X Ethernet,
|
n/a |
X5559A
[S]
|
375-3361
[C]
|
XFP Optical PCI-X Transceiver Single Mode Fibre, L |
n/a |
X7286A
[S]
|
371-0912
[F]
|
Low Profile PCI-X Single Gigabit Ethernet MMF, |
n/a |
12 If replacing X4444A with X4445A (same driver but different chip set), a reconfigure boot is required.
See Problem article 1003454.1.
13 Standard bracket 370-7665 is installed. Low-profile bracket 370-7792 is included. Order Option 4455A for factory integration.
|
Fibre Channel
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SG-XPCI1FC-EM4-Z Price
|
375-3398
[F]
|
4Gb PCI-X Single FC Host Adapter, |
n/a |
SG-XPCI1FC-QF4 Price
|
375-3354
[F]
|
4Gb PCI-X Single FC Host Adapter, |
n/a |
SG-XPCI2FC-EM4-Z Price
|
375-3399
[F]
|
4Gb PCI-X Dual FC Host Adapter, |
n/a |
SG-XPCI2FC-QF4 Price
|
375-3294
[F]
|
4Gb PCI-X Dual FC Host Adapter, |
n/a |
SG-XPCI1FC-EM2
[S]
|
375-3304
[F]
|
2Gb PCI-X Single FC Host Adapter, |
n/a |
SG-XPCI1FC-JF2
[S]
|
375-3156
[F]
|
JNI 2Gb PCI Single FC Host Adapter |
n/a |
SG-XPCI1FC-QF2
[S]
|
375-3102
[F]
|
2Gb PCI Single FC Host Adapter |
n/a |
SG-XPCI1FC-QL2
[S]
|
375-3383
[F]
|
2Gb PCI-X Single FC Host Adapter, |
n/a |
SG-XPCI2FC-EM2
[S]
|
375-3305
[F]
|
2Gb PCI-X Dual FC Host Adapter, |
n/a |
SG-XPCI2FC-JF2
[S]
|
375-3157
[F]
|
JNI 2Gb PCI Dual FC Host Adapter |
n/a |
SG-XPCI2FC-QF2
[S]
|
375-3108
[F]
|
2Gb PCI/PCI-X Dual FC Host Adapter |
n/a |
|
|
n/a |
SG-XPCI2FC-QF2-Z
[S]
|
375-3363
[F]
|
2Gb PCI/PCI-X Dual FC Host Adapter, |
n/a |
|
|
n/a |
X6727A
[S]
|
375-3030
[F]
|
PCI Dual FC Host Adapter+, L |
n/a |
X6767A 14
[S]
|
375-3102
[F]
|
2Gb PCI Single FC Host Adapter |
n/a |
X6768A 15
[S]
|
375-3108
[F]
|
2Gb PCI/PCI-X Dual FC Host Adapter |
n/a |
|
|
n/a |
X6799A
[S]
|
375-3019
16
[F]
|
PCI Single FC Host Adapter |
n/a |
14 X6767A changed to SG-XPCI1FC-QF2 in July 2003
15 X6768A changed to SG-XPCI2FC-QF2 in July 2003
16 375-3019 with SC connector is no longer available. The substitute adapter uses a smaller LC connector.
|
Graphics
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X3685A
[S]
|
375-3069
[F]
|
XVR-500 Graphics Accelerator |
n/a |
X3769A
[S]
|
375-3126
[F]
|
XVR-100 Graphics Accelerator (32MB) |
n/a |
X3770A
[S]
|
375-3181
[F]
|
XVR-100 Graphics Accelerator (64MB) |
n/a |
X3780A
[S]
|
375-3153
[F]
|
XVR-600 Graphics Accelerator |
n/a |
X7296A
[S]
|
375-3290
17
[F]
|
XVR-100 Graphics Accelerator (64MB), |
n/a |
17 Refer to FAB article 1001156.1> fuzzy or blurry video with the XVR-100 Graphics Accelerator.
|
I/O
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
501-5820
[F]
|
PCI I/O Riser Board |
n/a |
|
|
n/a |
Memory
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X7056A |
4 GB (4 × 1GB SDRAM DIMMs) |
501-7386
[F]
|
1GB SDRAM DIMM, L |
501-6109
[F]
|
X7051A
[S]
|
2 GB (4 × 512MB SDRAM DIMMs) |
501-7385
[F]
|
512MB SDRAM DIMM, L |
501-5030
[F]
|
X7051A-Z
[S]
|
2 GB (4 × 512MB SDRAM DIMMs), L |
501-7385
[F]
|
512MB SDRAM DIMM, L |
501-5030
[F]
|
X7056A-Z
[S]
|
4 GB (4 × 1GB SDRAM DIMMs), L |
501-7386
[F]
|
1GB SDRAM DIMM, L |
501-6109
[F]
|
X7058A-Z
[S]
|
8 GB (4 × 2GB SDRAM DIMMs), L |
540-6489
[F]
|
2GB SDRAM DIMM Assembly, L |
n/a |
|
|
n/a |
n/a |
501-5030
[F]
|
512MB SDRAM DIMM |
n/a |
n/a |
501-6109
[F]
|
1GB SDRAM DIMM |
n/a |
n/a |
540-5086
[F]
|
1GB SDRAM DIMM |
n/a |
n/a |
F511-1030 19
[F]
|
Package of 25 × 512MB SDRAM DIMMs |
n/a |
|
|
501-5030
[F]
|
n/a |
F511-1031 21
[F]
|
Package of 25 × 1GB SDRAM DIMMs |
n/a |
|
|
501-6109
[F]
|
19 See FAB article1000920 (formerly 201233) for details.
21 See FAB article1000920.1 (formerly 201233) for details.
|
Miscellaneous
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X9631A
[S]
|
595-6188 |
2-Post Rackmount Kit |
n/a |
Power
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
300-1632
[F]
|
1448W Power Supply |
n/a |
n/a |
300-1987
[F]
|
1448W Power Supply, L |
n/a |
n/a |
375-3168
[F]
|
Power Distribution Board, L |
n/a |
Rack
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SR9-XKL038A-IP |
595-6712
|
Sun Rack 900, Empty X-Option Rack without Power, |
n/a |
SF-XCAB
[S]
|
540-4613
|
Sun Fire Cabinet |
n/a |
SG-XARY030A
[S]
|
595-4706
|
72 inch Sun StorEdge Expansion Cabinet |
n/a |
n/a |
370-4427 25 26
[F]
|
4-Post Rack Kit
(370-4427-02 = 27") - discontinued June 2002
(370-4427-03 = 25") - obsolete
(370-4427-04 = 25") - add slide kit |
n/a |
25 Rack Mount Rail Kit 370-4427-02 is not compatible with the Sun Rack 900.
26 >=370-4427-03: Inner and Outer Slide Rails from the same manufacturer are required.
|
Removable Media
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
370-4412
27
[F]
|
Slimline 8X DVD-ROM / 24X CD-ROM |
n/a |
n/a |
390-0336
|
Slimline 8X DVD-ROM / 24X CD-ROM, |
n/a |
27 Only Toshiba model SD-C2732 has been confirmed as L
|
SCSI
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SGXPCI2SCSILM320-Z Price
|
375-3365
28
[F]
|
PCI Dual Ultra320 SCSI Adapter, L |
n/a |
SG-XPCI2SCSI-LM320
[S]
|
375-3191
[F]
|
PCI/PCI-X Dual Ultra320 SCSI Adapter |
n/a |
X1032A
[S]
|
501-5656
[F]
|
Single-Ended Ultra/Wide SCSI/FastEthernet (SunSwift PCI) |
n/a |
X2222A
[S]
|
501-5727
[F]
|
Dual FastEthernet / Dual SCSI PCI Adapter |
n/a |
X4422A
[S]
|
501-6635
[F]
|
Dual GigabitEthernet / Dual SCSI PCI Adapter |
n/a |
X6540A
[S]
|
375-0005
[F]
|
Dual Single-Ended Ultra/Wide SCSI (PCI) |
n/a |
X6541A
[S]
|
375-0006
[F]
|
Dual Differential Ultra/Wide SCSI (UDWIS/P)(HVD) |
n/a |
X6758A
[S]
|
375-3057 29
[F]
|
PCI Dual Ultra3 SCSI Host Adapter (LVD) |
n/a |
28 Ultra320 SCSI HBA (375-3365-01 REV 52) FCode 1.13 fails to work on all Sun Platforms, replace it with 375-3365-02 REV 50.
See Problem article 1013105.1.
29 The necessary drivers (SUNWqus, SUNWqusu, SUNWqusx, & SUNWqusux) and patches for this product are not included in Solaris 8 or 9, but must be downloaded. Please see How To article
1018123.1 for details.
|
System Board
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X7268A
[S]
|
CPU/Memory Board w/2× US IV 1050MHz, 8GB Memory |
501-6809
[F]
|
CPU/Memory Board w/2× US IV 1050MHz,
0MB |
n/a |
X7270A
[S]
|
CPU/Memory Board w/2 × US IV 1.35GHz, 8GB (16 × 512MB DIMMs) Memory |
501-6962
[F]
|
CPU/Memory Board w/2 × US IV 1.35GHz, 0MB
(Jaguar, 1.35GHz Lite 527-1164, Cinch socket) |
n/a |
X7270A-Z
[S]
|
CPU/Memory Board w/2 × USIV 1.35GHz,
8GB (16 × 512MB DIMMs) Memory, L |
501-7305
[F]
|
CPU/Memory Board w/2 × USIV 1.35GHz, 0MB
(Jaguar, 1.35GHz Lite 527-1164, Cinch socket), L |
n/a |
X7273A
[S]
|
CPU/Memory Board w/2 × USIV+ 1.5GHz, 8GB (16 × 512MB DIMMs) Memory |
501-7058
30
[F]
|
CPU/Memory Board w/2 × USIV+ 1.5GHz, 0MB |
n/a |
X7273A-Z
[S]
|
CPU/Memory Board w/2 × USIV+ 1.5GHz,
8GB (16 × 512MB DIMMs) Memory, L |
501-7481
[F]
|
CPU/Memory Board w/2 × USIV+ 1.5GHz, 0MB, L |
n/a |
X7274A
[S]
|
CPU/Memory Board w/2 × USIV+ 1.5GHz, 16GB (16 × 1GB DIMMs)Memory |
501-7058
31
[F]
|
CPU/Memory Board w/2 × USIV+ 1.5GHz, 0MB |
n/a |
X7274A-Z
[S]
|
CPU/Memory Board w/2 × USIV+ 1.5GHz,
16GB (16 × 1GB DIMMs) Memory, L |
501-7481
[F]
|
CPU/Memory Board w/2 × USIV+ 1.5GHz, 0MB, L |
n/a |
X7275A
[S]
|
CPU/Memory Board w/2 × USIV 1.35GHz,
16GB (16 × 1GB DIMMs) Memory |
501-6962
[F]
|
CPU/Memory Board w/2 × US IV 1.35GHz, 0MB
(Jaguar, 1.35GHz Lite 527-1164, Cinch socket) |
n/a |
X7275A-Z
[S]
|
CPU/Memory Board w/2 × USIV 1.35GHz,
16GB (16 × 1GB DIMMs) Memory, L |
501-7305
[F]
|
CPU/Memory Board w/2 × USIV 1.35GHz, 0MB
(Jaguar, 1.35GHz Lite 527-1164, Cinch socket), L |
n/a |
X7300A-Z
[S]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 8GB (16 × 512MB DIMMs) Memory, L |
501-7506 32
[F]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 0MB, L |
n/a |
501-7691 33
[F]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 0MB, L |
n/a |
501-7881 34
[F]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 0MB, L |
n/a |
X7301A-Z
[S]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 16GB (16 × 1GB DIMMs) Memory, L |
501-7506 35
[F]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 0MB, L |
n/a |
501-7691 36
[F]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 0MB, L |
n/a |
501-7881 37
[F]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 0MB, L |
n/a |
X7302A-Z
[S]
|
CPU/Memory Board w/2 × USIV+ 1.5GHz, 32GB (16 × 2GB DIMMs) Memory, L |
501-7481
[F]
|
CPU/Memory Board w/2 × USIV+ 1.5GHz, 0MB, L |
n/a |
X7303A-Z
[S]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 32GB (16 × 2GB DIMMs) Memory, L |
501-7506 38
[F]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 0MB, L |
n/a |
501-7691 39
[F]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 0MB, L |
n/a |
501-7881 40
[F]
|
CPU/Memory Board w/2 × USIV+ 1.8GHz, 0MB, L |
n/a |
n/a |
501-6963
[F]
|
CPU/Memory Board w/2 × US IV 1.35GHz, 0MB
(Jaguar, 1.35GHz Lite 527-1164, Tyco socket) |
n/a |
30 When installing X-options X7273A and X7274A in Sun Fire V490 servers, OBP must be upgraded to version 4.18.2. Please see FAB article 1000843.1 for details.
31 When installing X-options X7273A and X7274A in Sun Fire V490 servers, OBP must be upgraded to version 4.18.2. Please see FAB article 1000843.1 for details.
32 Manufacturing substitute part as of September 2006.
33 Primary part in September 2006, then Manufacturing substitute as of April 2007.
34 Primary part as of April 2007.
35 Manufacturing substitute part as of September 2006.
36 Primary part in September 2006, then Manufacturing substitute as of April 2007.
37 Primary part as of April 2007.
38 Manufacturing substitute part as of September 2006.
39 Primary part in September 2006, then Manufacturing substitute as of April 2007.
40 Primary part as of April 2007.
NOTE: Refer to the Sun Fire V490/V890 CPU/Memory Module Configuration Guide for Minimum Operating System and Firmware Versions
and supported Mixed-Speed Configurations.
|
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
|
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown
|
Code |
Manufacturing Part# |
Description |
NS |
340-6828 |
DVD-ROM/Smart Card Reader Carrier |
1 |
602-2560 |
Sun Fire V490 Base Model |
|
|
- FC-AL Backplane Power Cable
|
|
|
- FC-AL Backplane Data Cable
|
|
|
- Front Fan Tray Cable w/ Bracket 340-7241
|
- |
|
|
|
|
- PCI Riser Board Access Panel
|
|
|
|
|
|
|
|
|
|
|
|
|
NS |
|
|
NS |
|
|
NS |
|
- CPU Cover Lock Linkage Rod,
|
5 |
|
|
6 |
|
|
7 |
|
|
8 |
|
|
2 |
|
- Left/Right Front Dress Panel, 18 × 218 mm,
|
3 |
|
|
4 |
|
- Back Panel Status LED Assembly, L
|
|
|
- 4-Post Rack Kit
(370-4427-02 = 27") - discontinued June 2002
(370-4427-03 = 25") - obsolete
(370-4427-04 = 25") - add slide kit
|
9 |
|
|
10 |
|
|
NS |
|
- Removal Media Door w/o Bezel
|
NS |
|
|
NS |
|
- Keyswitch/Button/LED and Wire Harness
|
5 |
|
|
11 |
|
|
12 |
|
- Removable Media Bezel w/o V490 Nameplate,
|
14 |
|
|
NS |
|
|
NS |
|
|
NS |
|
- Shielded RJ45 to RJ45 Cable, 4M
|
NS |
|
- RJ45 to DB25 Serial Port Adapter,
|
NS |
330-3284 |
CPU/Memory Board Connection Cover |
NS |
375-3053 [F]
|
Removable Media Paddleboard and Cable, L |
NS |
530-3096 |
Power Cord IEC 320-C13 to IEC 320 Sheet E 2.5M, |
NS |
540-4713 |
CPU Access Panel |
42 Rack Mount Rail Kit 370-4427-02 is not compatible with the Sun Rack 900.
43 >=370-4427-03: Inner and Outer Slide Rails from the same manufacturer are required.
|
|