This section provides the most common repair procedures for the 
  Enterprise 4500. The written procedures below are links to the  Sun 
  Enterprise 6500/5500/4500 Reference Manual (805-2632).
Sun 
  Enterprise 6500/5500/4500 Reference Manual (805-2632). 
   
    | Component | Tips | 
   
    | CPU/Memory+ Board |  
        
           
            New service procedures are available for detached 
              heat sinks on EXX00 CPU and I/O boards (FIN I0683-1 ).
             | 
   
    | CPU Modules | 
         
          
         Sun Enterprise 6x00, 5x00, 4x00, 
          and 3x00 Systems Torque Screwdriver for UltraSPARC Module Installation 
          Guide 
           
             
               
                 
                  Specific error information must be returned 
                    with the 400MHz US-II CPU Modules at issue to ensure correct 
                    FRU repair (FIN I0984-1 ). 
           
             
              Tuning the ecache_scan_rate parameter of the Solaris 
                cache scrubber provides improved Ecache parity error protection 
                on non-mirrored SRAM UltraSPARC II-based systems (FIN I0755-1 ). 
           
            Any Fatal Reset errors in the UE 3X00 to UE 6X00 
              servers should be evaluated to determined whether it is because 
              of Ecache Tag error. Do not assume that a Fatal Reset error implies 
              that the system board is defective (FIN I0587-1 ). 
          The current diagnostic procedure to identify the faulty 
            CPU module from CPU Ecache parity errors is flawed, and it could easily 
            lead to the wrong CPU being replaced (FIN I0570-3 ). 
           
            Cleaning kit available for cleaning silicon oil 
              from CPU module on the system board (FIN I0567-1 ). 
             
          Failure to handle CPU Modules correctly can result 
            in physical damage; proper torquing techniques are required (FIN I0403-2 ). 
          Booting from the network can fail with Solaris 2.5.1 and Solaris 2.6 
          when using 464MHz or faster processors (FIN I0707-1).400MHz and 464/466MHz UltraSPARC II Modules in Enterprise Server platforms 
          may experience system reboots or system panics (FCO A0210-1). | 
   
    | Disk Board | 
        At system power up, the disk board does not turn on (FCO A0136-1).Ultra[TM] Enterprise x000 servers: Using show-disks to create devalias for Ultra disk board boot drive 
          (How To article 1001379.1).New disk board installed in a Sun Enterprise[TM] Server E4500/E5500/E6500 is not detected or recognized with probe-scsi-all.  Reference Problem article 1007581.1. | 
   
    | Disk Drive | 
        
           Improved firmware for Seagate 10K.6 disk drives will reduce the incidence of unexpected outages due to a spindle motor issue (FIN I1136-1 ).
          Improved drive firmware will reduce the incidence 
            of HDI failures on IBM Discovery disk drives (FIN I0955-1 ).18.2GB and 36GB IBM disk drives may be susceptible to early life failures 
          problem (FIN I0724-2). 
        Systems with 18.2GB and 36GB IBM disk drives may experience higher than expected failure rate.
           (FCO A0182-2).
        New disk board installed in a Sun Enterprise[TM] Server E4500/E5500/E6500 
          is not detected or recognized with probe-scsi -all (Problem article 1007581.1). | 
   
    | I/O+ Board | 
         
           
            Ultra Enterprise Exx00 I/O Boards can fail with 
              FEPS error during POST if installed in a slot where there are damaged 
              spring fingers (FIN I0800-1 ). 
          New service procedures are available for detached 
            heat sinks on EXX00 CPU and I/O boards (FIN I0683-1 ).Clarification of the hardware and software requirement to connect 
          the onboard SOC+ device on I/O boards used with an A3500FC StorEdge 
          Array (FIN I0586-1). | 
   
    | Memory | 
        
          Alternate 256MB DIMM part numbers are approved for use in 
          E3x00-E6x00 systems (FIN I1127-1 ).
           
          When using mixed density memory modules, certain combinations 
            of memory banks result in fatal reset while running POST before a 
            system boot (FIN I0588-1 ). 
           
          ECC Memory Error Guidelines for Enterprise servers 
            (FIN I0377-1 ).How to read prtdiag memory interleaving on Ultra servers (Problem article 1003210.1).
           Mitsubishi 256MB DIMMs (Sun p/n 501-5658) showing significantly
        lower than expected reliability (FCO A0258-1 ). | 
   
    | PCI Card | 
        Systems with a PGX PCI-based 8-bit Frame Buffer may display a vertical 
          black stripe when running the OpenWindows environment (FCO A0139-1).Sun Enterprise[TM] 3X00-6X00 servers: PCI i/o card address mapping on Ultra Enterprise servers (How To article 1010265.1). | 
   
    | Power/Cooling Module (PCM) | 
        Power/Cooling module handling and fault diagnosis N+1 configurations 
          may suffer a Silent Mode Failure (FIN I0599-1). | 
   
    | SBus Card | 
        Customers using SBus Dual FC Adapter (X6757A) at Rev. 50 may notice 
          slow performance on sequential write operations (FIN I0821-1).UDWIS SBus Host Adapter with isp-fcode 1.28 can cause "invalid command" 
          during probe-scsi-all or boot -hv from a StorEdge D1000 (FIN I0569-1).Sun FDDI SBus Adapter 5.0 SAS/DAS mounting screws may not fit the 
          EMI plate due to excessive plating (FIN I0469-1).SunATM-155 SBus board replacement may render interface unrecognizable 
          (FIN I0412-1).Large quantities of UDWIS/SBus Host Adapters installed may not come 
          up after reboot due to miscommunication between the SCSI host and the 
          target (FCO A0163-1). 
         | 
   
    | Tape Drive | 
        Firmware upgrade for EOL Mammoth 8mm tape drive (FIN I0516-1).All support calls related to the Exabyte Mammoth II tape drive need 
          to be forwarded to Exabyte (FIN I0719-1). |